background image

13 

 check that all metal elements are earthed,  

 clean the outside of the unit with a solvent-free product. A specific PAC NET cleaning kit is 

available as an optional extra (see §3.2), 

 check that the condensation is flowing out properly whilst the appliance is operating.  

 

3.2 Available accessories 

Naming 

Representation 

Item code 

PAC NET 

 

WMA03491 

Wintering cover 

 

W20HOUSSEPFIRST 

 

3.3 Recycling the product 

Your appliance is reaching the end of its working life

. You would like to get rid of it or 

replace it. 
Please do not throw it into the dustbin or into your local council’s selective sorting containers. 

When this symbol appears on a new appliance, it means that the equipment must not 
be thrown away and that it will be collected selectively so that it can be reused, 

recycled or recovered. Any substances it may contain which are potentially dangerous to the 
environment will be eliminated or neutralised. 

Enquire with your retailer for the conditions that apply to the recycling of your product and to the 
organisations that can handle its recycling. 

 

4. Warranties 

Principle 

Unless otherwise stipulated, we contractually guarantee the correct operation of our new Products. We 
guarantee that our Products conform to their technical specifications and that they are free of material 
and manufacturing default. 
The present warranty is limited, at our discretion, either to the repair or exchange for a new or repacked 
Product, or to the refund of any Products recognized as being defective by our services. Shipping 
expenses for the repaired or replaced Products delivered to the client will be borne by us, excluding any 
labour costs, travel and/or accommodation expenses incurred as the result of repairs made outside of 
continental France and excluding any payment of damages.  
All Product returns must first be approved and decided by our services. Returns sent by the Client 
without our prior approval will not be accepted. 
In particular, the spare parts warranty will only be honoured after analysis and expertise of the returned 
spare parts by our company followed by the decision to replace said parts. 
In all cases the seller's legal warranty will continue to apply. 
In order to benefit from the warranty, the Client and the End User agree to respect the following 
parameters concerning the balance of the swimming pool water: pH: 6.8 < pH < 7.6 ; free chlorine 

(*

 : < 

3,0 mg/L ; total bromine 

(*)

: < 5.0 mg/L ; stabilising agent (if used): < 75 mg/L ; total dissolved metals 

(iron, manganese, copper, zinc…) : < 0.1 mg/L  

(*): Cleaning robots must absolutely be removed from the pool before using a shock treatment. 
Note

: Using water drawn from a well is forbidden. 

 

General limitations 

The present warranty does not apply to visible defects that the Client failed to report upon accepting 
delivery of the Products. 
Also excluded from the warranty are: defects or deterioration due to the unsuitability of the Product with 
respect to the end User's needs, due to normal wear, to negligence, to incorrect installation or to a use 
that does not conform to the recommendations mentioned in the User Manual, to lack of maintenance 
and/or a handling accident, to incorrect storage, and/or by studies, instructions and/or specifications 
made by our Client. 

Содержание PF 6M-8M-11M-13M-15M

Страница 1: ...Installation instructions PF 6M 8M 11M 13M 15M Heat pump for swimming pools R f N C 014 A EN Ver 12 2010...

Страница 2: ...0 2 1 Statuses and faults of the regulator 10 2 1 1 Statuses 10 2 1 2 Faults 10 2 1 3 Display the values of sensors ST1 ST2 ST3 and ST4 11 2 2 Malfunctions of the appliance 11 2 2 1 The appliance does...

Страница 3: ...ing If the appliance has been tipped over express reserves in writing to the transporter Elimination or shunting of one of the safety leads automatically to the cancellation of the guarantee as for th...

Страница 4: ...1 with an ambient air of 15 C and a pool water of 26 C humidity 70 in compliance with the French NF 414 standard unit protection class IP 24 refrigerant gas R410A refrigerant charge see product name...

Страница 5: ...4 3 Installing the appliance installed the 5 anti vibration studs supplied see 1 1 2 put onto a stable solid concrete slab type and level surface preserve from risks of flooding due to condensation p...

Страница 6: ...5 1 1 Condensation drainage Caution your appliance can drain several litres of water per day and you are strongly advised to connect the drainage to the sewer connect a 18 interior pipe not supplied...

Страница 7: ...ing function Objective to keep the pool water at the required temperature independent of the filtering time the heat pump triggers the operation of the filter every hour the pool temperature required...

Страница 8: ...ing output terminals 16 17 heat pump B1 regulation electronic card see placing dimensions and description in the appendix Never power the filter pump motor directly through terminals 16 17 located on...

Страница 9: ...pressure to 150 g 0 150 bar open valves 2 3 and 4 completely then half open valve 5 see 1 4 4 the air accumulated in the heat pump condenser unit and in the filter circuit is then evacuated If valves...

Страница 10: ...by mode by pressing and holding for 3 seconds on then appears on the screen for 5 seconds before a small red dot appears open the valve 1 close valves 2 and 3 and open valves 4 and 5 if present ensur...

Страница 11: ...ect the sensor Switch the power supply off or press if dSA flashes Defrost sensor fault ST3 Sensor defective or disconnected terminals 4 6 of the plate B1 Replace or reconnect the sensor Switch the po...

Страница 12: ...an approved technician to check for the presence of an adequate quantity of refrigerant gas in the appliance Switch the power supply off or press if dtd flashes case after stand by following regulator...

Страница 13: ...if the outside temperature is lower than 12 C The evaporator is fouled Clean the evaporator 2 2 4 The heat pump trips out or attempts to start itself from time to time Causes Verification solution Th...

Страница 14: ...es Shipping expenses for the repaired or replaced Products delivered to the client will be borne by us excluding any labour costs travel and or accommodation expenses incurred as the result of repairs...

Страница 15: ...l installer excluding installation via retrofit kit for a period of two years starting from the date mentioned on the invoice as issued by our Client to the end User Users are also required to have an...

Страница 16: ...itrogen brazing etc all brazing work must be carried out by a qualified brazer welder in the case of units filled with R410A refer to the specific indications in the installation instructions this uni...

Страница 17: ...N o t e s N o t e n A a n t e k e n i n g N o t a s N o t a...

Страница 18: ...1 Electric diagram PF 6M 8M...

Страница 19: ...2 PF 11M 13M 15M...

Страница 20: ...Water flow adjusting probe NTC Regulation electronic card Pump control Fuse 3 15A T 250V 5 20 Fan capacitor Compressor capacitor Fan connector Fan Compressor Soft starter Black Blue Brown Grey White...

Страница 21: ...English Base Front pannel cowl Technical door Back pannel Post Grid Regulator 1 water pool inlet 1 water pool outlet Evaporator Stuffing box B1 regulation electronic card Fuse F1 Supply terminal boar...

Страница 22: ...N o t e s N o t e n A a n t e k e n i n g N o t a s N o t a...

Страница 23: ...N o t e s N o t e n A a n t e k e n i n g N o t a s N o t a...

Страница 24: ...023 49180 Saint Barth l my d Anjou cedex France www zodiac poolcare com Innovative pool products and services Produits et services innovants pour la piscine Votre installateur Your installer Plaque si...

Отзывы: