5
1.4.4 Hydraulic connections
The connection shall be by Ø 50 PVC pressure pipe, from a by-pass
, to the swimming pool filter
circuit, after the filter
and before the water treatment
:
PF
Hydraulic circuit pressure
Fittings
= inlet
= outlet
Average water
flow-rate
head
loss
test
operating
bar
bar
m³/h
mCE
6M
3 1.5
half union Ø50
fitting to stick
(see
parts
and
§1.1.2)
3 1.3
8M
4
1.4
11M
5 1.5
13M
6
1.5
15M
6.5 1.1
Condensation drainage:
Caution: your appliance can drain several litres of water per day, and you are strongly
advised to connect the drainage to the sewer.
connect a Ø18 interior pipe (not supplied), to the grooved end piece mounted on the
base of the appliance,
outlet: to the back or on the side :
The water treatment system (chemical or electro-physical disinfection)
must be installed
downstream from the heat pump
(see installation below),
and must be compatible with
it
(check with the manufacturer).
V1-V2-V3: by-pass valves
V5-V4: setting valves (optional)
*minimum distance
electrical protection boxes