Message
Possible cause
Soluti on
"---"
displayed
where
the ORP value
should be
Example display:
- - -
•
The
value measured is
0
.
•
The sensor has been automati cally blocked
by the pH overdose safeguard.
•
Check the connecti on between the sensor
and the control box, re-connect if necessary
(contact your retailer)
.
•
While waiti ng for a replacement sensor,
deacti vate the ORP functi on in the service
menu in order to switch to manual operati ng
mode (contact your retailer)
.
"pH dosing
STOP"
(
“INFO”
indicator
fl ashing)
•
The pH value measured remains higher
than the pH setpoint despite an injecti on
cycle customised by the pH overdose
safeguard.
•
Check or replace the container.
•
Check and adjust the alkalinity (TA) of the pool
water.
•
Check/clean or replace the pH sensor.
Tip: if you require assistance, inform your retailer about the appliance's conditi on to save ti me
8.2 I Wi-Fi LED behaviour
Control box status
Meaning
• The
LED is off
•
Appliance not connected or Wi-Fi network issue (modem malfuncti on,
changed network name or password, etc.)
•
Repeat the pairing process. If the LED is sti ll not lit despite the pairing att empt,
disconnect the reconnect the appliance to the mains power supply.
• The
LED is fl ashing
•
Pairing in progress. To stop pairing, disconnect the appliance from the power
supply.
• The
LED is on steady
•
Appliance connected to the Wi-Fi network and accessible via the app.
•
Pairing can be restarted regardless of the connecti on status by simultaneously pressing
+
for 4
seconds.