2.5.6 Connecti ng to an auxiliary device = AUX 1 - Dry contact provided for disconnecti on from the 230V
power supply (depending on the model)
The chlorinator manages a dry contact calibrated for disconnecti on from the 230V power supply. The power
supply is separated with its own protecti on (circuit breaker calibrated to suit the equipment controlled or its
transformer – max. 8 A).
Preferred connecti on for NL LED spotlights.
Possible controls:
ON/OFF with ti mer for all monochromati c spotlights, ON/OFF/Colour with NL RGBW LED
spotlights
230 V contact
All types of auxiliary
device
230 V
Transformer for lighti ng,
booster pump, etc.
maximum 8 A
Preferred connecti on for Zodiac® NL LED spotlights (see
installati on manual)
: 230 VAC/12 VAC
(50/60 Hz) transformer
: Electrical protecti on
: Auxiliary relay for
external controller or
switch
With 2 spotlights
With 1 spotlight