9
2.1.2 GenSalt OT cell
16.5 cm
22.5 cm
27.5 cm
7.5 cm
27.5 cm
12.5 cm
•
The cell must be installed on a horizontal pipe so as to guarantee that the water fl ow passing therethrough
is primarily horizontal, and that the angle/slope does not exceed 30°. The pipe must have a free horizontal
length of at least 30 cm, on which the cell will be installed. The cell must also be installed as far as possible
from any right angle or curve formed in the piping (
).
•
Respect the water fl ow directi on (see arrows (
)).
INLET
OUTLET
30°
0°
30°
max.
max.
•
Dismantle the cell (
).
•
Positi on the EU pipe adapter (DN50 mm) upside down at the positi on where the pipe (
) will be installed.
•
Use a drill bit or centre-punch to mark the positi ons of the holes to be drilled on the pipe, remove the EU
pipe adapter (DN50 mm) and drill the holes using the hole saw supplied.
•
Check that the edges are perfectly smooth and deburred (use abrasive paper for example).
•
Clip together the lower and upper parts of the cell collar on the pipe at the holes, respecti ng the water fl ow
directi on (use the "EU" Ø50 adapter for a Ø50 mm pipe).
•
Positi on the top transparent part of the cell (presence of a foolproof locati ng notch), positi on the
compression ring on the thread of the upper collar by aligning the point (
) of the collar with the arrow
of the collar (
), then ti ghten fi rmly by hand (do not use a tool).
•
Connect the cell power cord in compliance with the wire colour codes (red, black and blue connector(s))
and then fi t the protecti ve cap.
For GenSalt OT 10,
the second red connector will not be connected; leave
it as it is before positi oning the protecti on cover.
EN