5.4.4 "Cover" mode
If the pool is equipped with a compati ble electric shutt er (contact closed = shutt er closed), it can be connected to the
appliance in order to automati cally reduce chlorinati on when closed. This is known as "
Cover"
mode. Chlorinati on will
resume at the level determined by the programmes on opening the compati ble electric shutt er.
Producti on in
"Cover"
mode can be confi gured in the setti ngs of the main menu from
"Low/Cover"
mode.
"Low/Cover"
mode can be confi gured from 0% to 30% in intervals of 10%. The programmes remain acti ve when the
appliance is in
"Low/Cover"
mode.
Check that the shutt er is compati ble and is connected to the appliance
on the low-voltage circuit, see
“2.5 I
Electrical connecti ons”.
"Cover"
mode is automati cally acti vated when the shutt er is closed. The message
"Cover"
mode and the producti on rate
are displayed on the screen.
"Cover"
mode will end as soon as the shutt er is completely open.
If the appliance is equipped with a Dual Link module, we recommend not connecti ng
"Cover"
mode. More specifi cally,
chlorinati on is managed by the Dual Link module. In cases where
"Cover"
mode is connected in the presence of a Dual
Link module, chlorinati on will be performed when the shutt er is closed, even if the ORP measurement is greater than
the setpoint value.
5.4.5 "Cold water" safeguard (depending on the model)
In additi on to displaying the water temperature, the temperature sensor is used to protect the cell, which is sensiti ve to
cold water (reduced conducti vity between the plates and thus an increase in voltage).
The temperature displayed in the top left corner of the home screen starts to fl ash at 15°C.
When the water temperature is less than or equal to 15°C, chlorine producti on automati cally switches to the rate defi ned
in
"Low"
/
"Cover"
mode (between 0 and 30%).
When the water temperature is less than or equal to 10°C, chlorine producti on stops. The absence of chlorinati on at this
temperature is not an issue since bacterial development is slowed in cold water.
In additi on to the fl ashing temperature display, the message
"LOW TEMPERATURE"
is displayed intermitt ently.
When the temperature rises to above 10°C, the producti on rate is set to
"Low"
/
"Cover"
When the temperature rises to above 15°C, chlorinati on is resumed at the operati ng rate set via the programmes.
5.4.6 Locking the interface
The appliance can be locked, which deacti vates the butt ons on the user interface panel. Press both butt ons
and
simultaneously for 3 seconds. This functi on can be accessed from any screen/menu.
Locking the appliance automati cally redirects the user to the home screen. Press both butt ons
and
simultaneously
for 3 seconds to unlock the appliance.