9
Output Lights Will Not Go Down
Is Chlorinator in super-chlorinate mode?
YES
NO
Press super-chlorinate button once to take
chlorinator out of super-chlorinate mode.
Check touch pad PCB.
(see Touch Pad PCB pg. 14)
Amber Output Light is Blinking
Chlorinator is in a rest mode before it
reverses polarity. Wait 5-10 minutes
and check again.
OR
Press and hold service button
(located 1” to the right of the ON/OFF switch
and the Nature2 Reset switch )
to speed up the reversing process.
(see Reversing Polarity pg. 13)
Transformer
Testing
(see Testing Power Path pg . 5)
Replacement
1 . Disconnect power supply .
2 . Remove chlorinator from wall .
3 . Remove 4 screws to remove cover .
4 . Remove ribbon wire connector from power PCB and set cover aside .
5 . Disconnect the 5 wires from the transformer (keep track of each wire location for reassembly) .
6 . Turn over powerpack, remove screw from the center of the transformer and remove the transformer .
7 . Mount new transformer using the nut & bolt .
8 . Attach wires from new transformer to correct plastic terminals .
9 . Attach ribbon wire connector .
10 . Attach cover with 4 screws .
11 . Replace chlorinator on wall .
12 . Reconnect power supply .