INSTALLATION AND OPERATING INSTRUCTIONS
Страница 1: ...1 I NSTAL INSTALLATION AND QL 420 540 CARTRIDGE FILTER INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS...
Страница 2: ...e filter or any other service of the circulating system TURN THE PUMP OFF and shut OFF any automatic controls to ensure the system is NOT inadvertently started during the servicing Open the AIR BLEED...
Страница 3: ...After turning off and isolating the filter pump cleaning is achieved by removing the clamp band lifing off the filter lid removing the four filter elements and hosing off dirt and debris with a high p...
Страница 4: ...Before repositioning valve s and before beginning the assembly or disassembly or adjustment of the clamp or any other service of the circulating system 2 Turn the pump OFF and shut off any automatic...
Страница 5: ...the filter element when doing so 7 Replace the cartridges into the filter ensuring they are correctly located on the bottom spigot of the filter 8 Refit the top manifold ensuring it is correctly fitt...
Страница 6: ...pressure cleaner or purpose made element cleaner Every 3 Months Check inlet outlet o rings for leaks Check operation of pressure gauge salt water can prematurely reduce the life of a gauge Isolate Pu...