fluidra Astralpool Viron QL 420 Скачать руководство пользователя страница 2

INST 371 VIRON QL Cartridge Filter V08-20 

 

IMPORTANT SAFETY PRECAUTIONS 

ATTENTION INSTALLER: This guide contains important information about the installation, operation and safe use of this 
product. This information should be given to the owner and/or operator of this equipment after installation or left on or 
near the filter. 
ATTENTION USER: This manual contains important information that will help you in operating and maintaining this filter. 
Please retain it for future reference. 
 

 

WARNING

- Before installing this product, read and follow all warning notices and instructions which are included. 

Failure to follow safety warning and instructions can result in severe injury, death or property damage.

  

OWNER INFORMATION AND SAFETY 

The VIRON QL Cartridge filter is designed and manufactured to provide many years of safe and reliable service when 
installed, operated and maintained according to the information in this manual and the installation codes referred to in later 

sections. Throughout the manual, safety warnings and cautions are identified by the  

  symbol. Be sure to read and 

comply with all of the warnings and cautions. 

 WARNING

: Do not operate the filter until you have read and understand clearly all the operating instructions 

and warning messages for all equipment that is a part of the pool circulating system. The following instructions are intended 
as a guide for initially operating the filter in a general pool installation, however each installation may have unique conditions 
where the starting procedure could be different. Failure to follow all operating instructions and warning messages can result 
in severe injury, death or property damage. 
 

 

  

WARNING:

 THIS FILTER OPERATES UNDER HIGH PRESSURE. 

When any part of the circulating system, (filter, pump, valves, clamp etc) are serviced, air can enter the system and become 
pressurized. Pressurized air can cause the lid to be blown off, which can result in severe injury, death, or property damage. 
To avoid this potential hazard, please follow these instructions. 

1.

 

Before repositioning valve(s) and before beginning the assembly, disassembly or adjustment of the clamp of the filter 
or any other service of the circulating system, TURN THE PUMP OFF and shut OFF any automatic controls to 
ensure the system is NOT inadvertently started during the servicing, Open the AIR BLEED VALVE in the top of the 
filter lid and wait until all pressure is relieved. 

2.

 

Whenever installing the filter clamp, follow the filter clamp installation instructions exactly. 

3.

 

Once service on the circulating system is complete, FOLLOW THE RESTART INSTRUCTIONS EXACTLY 

4.

 

Maintain circulation system properly. Replace worn or damage parts immediately 

5.

 

Be sure that the filter is properly mounted and positioned according to instructions provided.    

 

WARNING:

 Due to the potential risk that can be involved, it is recommended that the pressure test be kept to 

the minimum time required by the local code. Do not allow people to work around the system when the circulation system 
is under pressure test. Establish a barrier and post warning signs around the pressurized equipment. If the equipment is 
located in a plant room, lock the access doors and post warning signs. 
Never attempt to adjust any closures or lids or attempt to remove or tighten bolts on the system when pressurized. These 
actions can result in a separation or failure of the system components. This instantaneous release of pressure can cause 
components to be accelerated to high velocities and to travel great distances. These components could cause severe 
personal injury or death if they were to strike a person. 
 

 

 

WARNING:

 Risk of electrical shock or electrocution. 

This pool filter must be installed by a qualified pool serviceman in accordance with the National Electrical Code (NEC) and 
all applicable local codes and ordinances. 
Always disconnect power to the pool equipment at the circuit breaker before servicing any of the equipment. Ensure that 
the disconnected circuit is locked out or properly tagged so that it cannot be switched on while you are working on the 
pool equipment. Failure to do so could result in serious injury or death to service people, pool users or others due to 
electric shock. 
 
Position the filter and the air relief valve to safely direct water drainage and purged air or water. Water discharge from an 
improperly positioned filter or valve can create an electrical hazard that can cause severe personal injury as well as damage 
property. 

USA  QL 

CARTRIDGE FILTER 

Содержание Astralpool Viron QL 420

Страница 1: ...1 I NSTAL INSTALLATION AND QL 420 540 CARTRIDGE FILTER INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS...

Страница 2: ...e filter or any other service of the circulating system TURN THE PUMP OFF and shut OFF any automatic controls to ensure the system is NOT inadvertently started during the servicing Open the AIR BLEED...

Страница 3: ...After turning off and isolating the filter pump cleaning is achieved by removing the clamp band lifing off the filter lid removing the four filter elements and hosing off dirt and debris with a high p...

Страница 4: ...Before repositioning valve s and before beginning the assembly or disassembly or adjustment of the clamp or any other service of the circulating system 2 Turn the pump OFF and shut off any automatic...

Страница 5: ...the filter element when doing so 7 Replace the cartridges into the filter ensuring they are correctly located on the bottom spigot of the filter 8 Refit the top manifold ensuring it is correctly fitt...

Страница 6: ...pressure cleaner or purpose made element cleaner Every 3 Months Check inlet outlet o rings for leaks Check operation of pressure gauge salt water can prematurely reduce the life of a gauge Isolate Pu...

Страница 7: ...INST 371 VIRON QL Cartridge Filter V08 20 7...

Страница 8: ...INST 371 VIRON QL Cartridge Filter V08 20 8 Fluidra Group Australia Pty Ltd 219 Woodpark Road Smithfield N S W 2164 ABN 087 002 641 965...

Отзывы: