3
Table of Contents
Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Look /Feel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Circuit Breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Power Cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Testing Power Path . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Chlorinator Not Operating . . . . . . . . . . . . . . . . . . . . . . . . 6
No chlorine reading . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Output Lights will Not go to 100% . . . . . . . . . . . . . . . . . 8
Output Lights will Not go Down . . . . . . . . . . . . . . . . . . . 9
Amber Output Light Blinking . . . . . . . . . . . . . . . . . . . . . . 9
Transformer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
No Flow Light Is On . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Add Salt Light Is On . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Add Salt Light and/or No Flow Light Are On . . . . . . . . 11
Chlorine reading too high . . . . . . . . . . . . . . . . . . . . . . . 12
Calcium Build-up On Cell . . . . . . . . . . . . . . . . . . . . . . . 12
Reversing Polarity . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Cleaning/Replacing Cell . . . . . . . . . . . . . . . . . . . . . . . . 13
Touch Pad PCB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
To Replace the Clear Cover . . . . . . . . . . . . . . . . . . . . . 15
PCB Replacement for DuoClear . . . . . . . . . . . . . . . . . . 16
Triac Screws . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Exploded Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Look/Feel
Before removing chlorinator cover, check the following:
1 . Is the pool pump on?
2 . Is the chlorinator turned on?
3 . Do the indicator lights function? (If NO, see Output Lights pg . 8-9)
(If all of the above answers are “YES”, there is no problem with the chlorinator. Have the consumer bring a water
sample to their dealer for analysis.)
4 . Is the circuit breaker tripped? (see Circuit Breaker pg . 4)
5 . Is the output cord damaged or the plug cap not properly attached?
(see No Flow Light Is On pg . 10)
6 . Is there calcium built-up on the cell? (see Calcium Build-up
on Cell pg . 12)
After checking the above items:
1 . Turn off power supply .
2 . Remove 4 screws to remove cover and hang cover
from venting with “S” hooks provided in kit .
Do not disconnect ribbon wire . Check the following:
• Are there any visible burn marks?
• Is there any visible water damage?
• Are there any loose wires or screws?