Output Lights Will Not Go To 100%
Is salt level 4000 ppm or higher?
YES
NO
Add salt according to chart
in Owner’s Manual.
Check there is 220V incoming power.
YES
NO
Is water temperature below 65˚ F?
YES
NO
Add salt to compensate.
Cell may be nearing the end of its life. Check
cell age, run time & output setting.
Replace cell. (see Cell pg. 13)
If unit is less than 1 year old check
the following:
Check touch pad PCB.
(see Touch Pad PCB pg. 14)
Replace power PCB.
(see Power PCB pg. 16)
Have qualified electrician
rewire chlorinator to 220V.