ZMIO310 Vertical Bus Expansion Module User Manual V1.0
5.3.
Read & Write Digital, Analog
Expanded IO, AD and DA can be operated through input and output instructions, like, IN,
OP, AIN, AOUT.
Check and set AD, DA module range through CANIO_INFO (can id, 17, submodule address),
for more details, please refer to Basic Manuals.
5.4.
Local Behind-level Expansion Address Description
After coupler module is power-on, it will scan local back-level expansion interface,
and it will assign one expansion address for each scanned expansion submodule.
→
Expansion example:
Like, the local back-level interface of ECAT communication module (ZMIO310-ECAT)
connects to 3 input modules (ZMIO310-16DI), 2 output modules (ZMIO310-16DO /
ZMIO310-16DOP), 1 AD module (ZMIO310-4AD) and 1 DA module (ZMIO310-4DA) in turn.
ECAT communication module starts to scan and assigns address when it is power-
on. The submodule address is assigned starting from 0, then assign the address
according to the connection sequence, that is, the expansion address of the first input
module is 0, the expand address of DA module is 6.
Module sequence
Model name
Assigned address
ECAT Coupler
ZMIO310-ECAT
/
The first submodule
ZMIO310-16DI
0
Type
Relative Module
Exact model
Instruction Permission
View
Input
DI module
ZMIO310-16DI
IN
Read Only
IN
Output DO / DOP module
ZMIO310-16DO
ZMIO310-16DOP
OP
Read & Write
OUT
AD
AD module
ZMIO310-4AD
AIN
Read Only
AD/DA
DA
DA module
ZMIO310-4DA
AOUT
Read & Write AD/DA