![Zmotion ZMIO300 Series Скачать руководство пользователя страница 54](http://html1.mh-extra.com/html/zmotion/zmio300-series/zmio300-series_hardware-manual_3937327054.webp)
ZMIO300 Series Hardware Manual Version 1.8
54
12
Channel 2, 3 open
13
Channel 0, 2, 3 open
14
Channel 1, 2, 3 open
15
All channels open
→
*3 data value meaning:
Data value
Meaning
0×0000 to 0×FFFF
Scale value of this channel
➢
Each index is related to each channel
DA module
Index
(hex)
Subindex
(hex)
Object name
Default
value
Data range
Data type
Permission
5001
(for
example)
00
CONFIG_DATA
2
2
UNSIGNED 8
Be read
01
CONFIG_1_
INDENT
10
10 to
15*1
1
UNSIGNED
16
Read/write
02
CONFIG_2_
INDENT
0
0
Read/write
Index
(hex)
Subindex
(hex)
Object name
Default
value
Data
range
Data type
Permission
7001
(for
example)
00
OUT_GENERIC
4
4
UNSIGNED
8
Read/Write
01
OUT_GEN_INT1
0
0×0000 to
0×FFFF*2
UNSIGNED
16
02
OUT_GEN_INT2
03
OUT_GEN_INT3
04
OUT_GEN_INT4