ZMIO300 Series Hardware Manual Version 1.8
44
4.3
IO and Analog Monitor (watch)
Expanded IO, AD and DA can be operated through input and output relative
instructions, like, IN, AIN, AOUT.
(Please see ZBasic Manuals for details.)
4.4
Expansion Address Description
After coupler module is power-on, it will scan local back-level expansion interface,
and it will assign one expansion address to each scanned expansion submodule.
→
Expansion example:
Like, the local back-level interface of ECAT communication module (ZMIO300-
ECAT) connects to 3 input modules (ZMIO300-16DI), 2 output modules (ZMIO300-
16DO / ZMIO300-16DOP), 1 AD module (ZMIO300-4AD) and 1 DA module
(ZMIO300-4DA) in turn.
ECAT communication module starts to scan and assign address when it is power-
on. Assign the address according to the connection sequence, starting from 1. The
expand address of the first input module is 1, the expand address of AD module is 6.
➢
This expand address is used to build data dictionary, and the address assign is not
influenced by expansion submodule type.
➢
ZCAN communication module only assigns address for internal control.
Type Relative Module
Exact model
Instruction
View
Input
Input module
ZMIO300-16DI
IN
Input view
Output Output module
ZMIO300-16DO
ZMIO300-16DOP
OP
Output view
AD
AD module
ZMIO300-4AD
AIN
AD/DA view
DA
DA module
ZMIO300-4DA
AOUT
AD/DA view