ZMC212BE Motion Controller User Manual V1.5
⚫
Please be sure to connect the public end of each communication node to prevent the
communication chip from burning out.
⚫
Please use twisted-pair shielded cables, especially in harsh environments, and make
sure the shielding layer is fully grounded.
→
Cable Requirements:
Twisted pair shielded wire, and shielded cable grounded.
3.2.2.
Basic Usage Method
(1)
Please follow the above wiring instructions for correct wiring.
(2)
After power on, please use ETHERNET, RS232 (default parameter, it can be connected
directly) and RS485 (default parameter can be directly connected, one adapter is
needed for hardware) to connect to ZDevelop.
(3)
Please use the "ADDRESS" and "SETCOM" commands to set and view the protocol
station No. and configuration parameters, see "ZBasic Programming Manual" for
details.
(4)
Correctly set the relevant parameters of the third-party equipment according to their
respective instructions to match the parameters of each node.
(5)
When all are configured, it
’s time to do
communicating.
(6)
Communication data of RS232 can be directly viewed through “ZDevelop / Controller
/ State the Controller / CommunicationInfo”.