ZMC212BE Motion Controller User Manual V1.5
voltage (E+24V port) is 24V.
→
Wiring Reference
→
Wiring Note:
⚫
The wiring principle of general input (IN0-23) is shown in the figure above. The
external signal source can be an optocoupler or a key switch or sensor, etc., all can
be connected as long as the output level meets the requirements.
⚫
For the public end, please select the "EGND" port on the IO power supply terminal to
connect to the "COM" terminal of the external input device. If the power supply of the
signal area of the external device and the power supply of the controller are in the
same power supply system, this connection can also be omitted.
3.4.2.
Basic Usage Method
(1)
Please follow the above wiring instructions for correct wiring.
(2)
After power on, please use any of the three interfaces ETHERNET, RS232 and RS485
to connect to ZDevelop.
(3)
State values of relative inputs can be read directly through “IN” command, also, it can
be read through “ZDevelop/View/In”. Please refer to “ZBasic” for details.
Содержание ZMC212BE