ZMC212BE Motion Controller User Manual V1.5
Output frequency
<
8kHz
Output voltage level
DC24V
Max output current
+300mA
Max leakage current when OFF
25μA
Respond time to ON
12μs
Respond time to OFF
80μs
Overcurrent protection
Support
Isolation method
Optical isolation
Note:
The times in the table are typical values based on the resistive load, and may
change when the load circuit changes.
Due to the leak-type output, the shutdown of the output will be more obviously
affected by the external load circuit, and the output frequency should not be set
too high in the application.
→
Wiring Reference
→
Wiring Note:
⚫
The wiring principle of general output OUT0-7 is shown in the figure above. The
external signal receiving end can be an optocoupler or a relay or solenoid valve, all
can be connected as long as the input current does not exceed 300mA.
⚫
For the connection of the public end, please select the "EGND" port on the IO power
terminal to connect to the negative pole of the DC power supply of the external input
device. If the DC power supply of the external device and the controller power supply