all kinds of data frame trigger modes can be configured. 

CAN-FD 

CAN-FD protocol has three data types: CANH, CANL and CAN-DIFF .The 

normal Baud rate and FD Baud rate should be set and the start bit triggering and 

all kinds of data frame triggering can be configured. 

LIN 

LIN protocol support LIN1.1 and LIN1.3 version, LIN bus synchronization 

interval, synchronous field, specific ID, specific ID + specific data within the 

1Mb/s can be triggered. 

Flex Ray 

Flex Ray has one data line TXD .Flex Ray bus within 20Mb/s can be triggered in 

the TSS and frame ID. 

USB 

USB has two sources, including D+ and D-. 

USB2.0 (low speed +full speed) bus output packet, input packet, start packet, 

setup packet, DATA0, DATA1, response packet, no response packet, stop 

packet, preamble packet ,package synchronization and package terminator 

within 20Mb/s can be triggered. Each triggering mode can further specify the 

specific information of the corresponding packet, for example, the start packet to 

set the expansion parameters and account values, the setup package to set the 

expansion parameters, address values and port values. 

SD_SPI 

SD_SPI has two sources, including clock source and command source. 

On the 20Mb/s SD bus (SPI mode), the specific command or specific command 

+ parameter can be triggered and decoded. 

SD_SD 

On the 20Mb/s SD bus (SD mode), the specific command or specific c 

parameter can be triggered. 

Wiegand 

Triggers when the specified OEM, FC, CC segmen ten countered on the 

Wiegand bus(26Bit, 39Bit, 44Bit or customized frame format), or data is the 

specified value. Supports for masking certain fields as needed. 

DS18B20 

DS18B20 has one data channel. The temperature resolution of 

9,10,11,12bitscan be set for decoding .The start bit, the specified ROM 

command and the specified RAM command on the DS18B20 bus can be 

triggered. 

PS/2 

PS/2 has two sources, including clock source and data source. 

The start bit and data on the PS/2 bus within 1Mb/s can be triggered, which 

support triggering from the host to slave and from the slave to host. 

MDIO 

MDIO has two sources, including clock source MDC and data source MDI. 

Supports triggering for ST segment, OP segment, PHYAD segment, REGAD 

segment and DATA segment on the MDIO bus, and they can be decoded in both 

LSB and MSB modes. 

DALI 

DALI has one data source. Triggers for decoding when the specified Forward19, 

Forward27, Backward frame en countered on the DALI bus. 

Содержание ZDS2000B Series

Страница 1: ...ZDS2000B Series Oscilloscope User Manual Date 2020 01 06 V1 02 Guangzhou ZHIYUAN Electronics Co Ltd www zlg cn User Manual UM01010101...

Страница 2: ...on 9 Chapter 3 Function Description 13 3 1 z Explore Waveform Zoom 13 3 1 1 Waveform Zoom 13 3 1 2 Search and marking 15 3 2 Segmented storage funciton 16 3 3 Waveform search 17 3 4 Parameter measurem...

Страница 3: ...he protective grounding wire of its power cord In order to avoid electric shock make sure the power cord ground wire is properly connected with protective earth terminal before connecting any input an...

Страница 4: ...antly to keep the instrument ventilated Do not use the instrument in a wet environment In order to avoid the risk of short circuit and electric shock do not operate the instrument in a wet environment...

Страница 5: ...ing signs and meanings CAUTION CAUTION symbol indicates a hazard Improper handling or execution in a specified process operation and so on can lead to loss of important data or damage to the instrumen...

Страница 6: ...ation Input Power ON OFF USBPort 40 years of use recyclable Do not throw the used battery into garbage bin CE Certification Each channel has 1M input resistor and 16pF input capacitor All inputs are 3...

Страница 7: ...on box switch and fixed facilities such as those stationary motors permanently attached to fixed facilities IV CAT IV It is applicable to measure for the terminal of the low voltage facilities Measure...

Страница 8: ...ature please make sure the air inlet and vent of the product keep the air flow freely When using the oscilloscope on the work bench please leave at least 10cm gaps on the top back and both sides of in...

Страница 9: ...you can quickly view and locate abnormal signals Waveform play function In ZOOM mode use the waveform play function to quickly browse the whole waveform signal trends etc Analysis function ZDS2000B os...

Страница 10: ...and knob B mainly perform menu selection or Knob A performs fine tune and Knob B performs coarse tune 4 Shortcut function keys These keys are mainly used to perform One key clearing One key persistenc...

Страница 11: ...150Vrms Connecting mode Make the BNC female of the external interface connected with the BNC terminal of the oscilloscope Turn the knob to right and lock it 11 Analog channel input terminal These inpu...

Страница 12: ...appropriately and use them as the bracket to make the oscilloscope upward sloping so as to leave the oscilloscope stableness for better operation and observing the display screen Open the supporting f...

Страница 13: ...but also use an oscilloscope to automatically and conveniently analyze the abnormality in waveforms enabling users to locate abnormal signals within millions of waveforms without any effort Figure 3 1...

Страница 14: ...zoom view mode is selected users can adjust the size of zoom window to view the waveform details Figure 3 3 Horizontal control area 2 Waveform translation in the zoom mode The large knob and time bas...

Страница 15: ...n but ton with the same direction as the secondary time base waveform play to increase the waveform play speed The more times the button is pressed the faster the waveform is played Press the backward...

Страница 16: ...ong time and then the waveform appears along with interference as shown in Figure 3 7 In order to facilitate analysis and save storage space the segmented storage is used to record each section of wav...

Страница 17: ...eries oscilloscope has powerful real time hardware search function It provides many waveform search modes including edge pulse width cycle frequency rising falling time duty cycle and runt and sets th...

Страница 18: ...nterface 3 5 Cursor Measurement Users can use the cursor measurement function to measure the X axis values such as time and Y axis values such as voltage of selected waveforms There are two pairs of m...

Страница 19: ...ng Users can easily find the communication error debug hardware and accelerate the development progress through this function as shown in Figure 3 13 ZDS2000B series oscilloscope can perform 27 protoc...

Страница 20: ...2 4 Analog bandwidth 3dB 200MHz 200MHz Calculated rising time 1 75ns 1 75ns Vertical resolution 8 bit Bandwidth limit 20MHz OFF Input coupling DC AC GND Input impedance 1M 1 16pF 4pF Input sensitivit...

Страница 21: ...eal time sampling Maximum sampling rate 2GSa s single channel 1GSa s Multiple channel Memory depth ZDS2022B Plus ZDS2024B Plus Single channel 1 4Kpts 14Kpts 140Kpts 1 4Mpts 14Mpts 28Mpts 56Mpts 125Mpt...

Страница 22: ...gand FlexRay DS18B20 PS 2 MDIO DALI HDQ 1 Wire IrDA Manchester DHT11 SHT11 Figure 4 6 Basic trigger type description Trigger Type Symbol Description Edge trigger Includes rising edge trigger falling e...

Страница 23: ...unication Manchester Diff Manchester WIEGAND Miller Photo electricity DALI Infrared NEC Infrared transfer protocol analysis Philips RC 5 Philips RC 6 Industrial automation RS485 RS232 485 and 232 use...

Страница 24: ...etup package to set the expansion parameters address values and port values SD_SPI SD_SPI has two sources including clock source and command source On the 20Mb s SD bus SPI mode the specific command o...

Страница 25: ...rt bit of the specified package is triggered on differential Manchester bus DHT11 DHT11 has one data source The start bit is triggered on the DHT11 bus SHT11 SHT11 has one data source The specified co...

Страница 26: ...s at the same time Measurement Statistics Current value maximum minimum average value standard deviation statistic times Hardware frequency meter Supported The maximum frequency is the oscilloscope ba...

Страница 27: ...escription Temperature range Operation 10 40 Storage 20 70 Ingress Protection Rating IP20 Humidity range 60 relative humidity Cooling method Fan Altitude Less than 3000m operating less than 12000m non...

Страница 28: ...on cable Communication between PC and oscilloscope Probe Standard configuration of a200MHz passive probe X1 and X10 range for each channel Power line For the power supply of an oscilloscope Informatio...

Страница 29: ...individual or unit unauthorized commercial use of this document without prior consent of ZHIYUAN Electronics is all borne by the individual or unit themselves ZHIYUAN Electronics and partner companie...

Отзывы: