33
©2017 Guangzhou ZHIYUAN Electronics
Date: 2017/05/22
User Manual
V1.00
Guangzhou ZHIYUAN Electronics Co., Ltd.
CAN-bus recording analyzer
CANREC User Manual
continuously save all waveforms on the CAN-bus into the SSD without dead zone
after the operation is started. When there is error frame, all waveform recorded before
and after error occurrence can be observed.
Figure 5- 38: Continuous storage mode
5.7.12
Trigger Storage Mode
Figure 5- 39 shows the trigger storage mode. In this mode, after the operation is
started, the CANREC saves the waveforms on the CAN-bus under the trigger
condition of an error or a specific message, and pre-triggers to save one message
length of waveform, i.e., save the waveform of previous frame (before the error
frame). All waveforms are saved into the SSD. This mode is usually used for
long-time data waveform storage, which facilitate users to find the accidental fault
and its cause.
Figure 5- 39: Trigger storage mode