background image

Swing Gate Opener

User Manual

P a g e

| 26

Copyright©2022 ZKTECO CO., LTD. All rights reserved.

Open/Close/Stop

Open/Close/Stop

Close

Close

Open

Open

Pedestrian

Pedestrian

Stop

Stop

four

four channel

channel

remote

remote

(R1

(R1 mode)

mode)

single

single channel

channel

remote

remote

Control Board Settings

5.7.1

Base Menu

At the Initial display

, push enter button TS2 once for at least 1 second to enter the base menu.

is on the display, with up/down its possible to select other functions of this menu.

To exit this menu, select or push up and down together.

After 2 minutes without actions, the control unit exits itself from this menu.

Menu

Push TS2 once

for at least 1

second to enter

the base menu.

Option

Push TS1 or TS3 to select.

Push TS2 to enter.

Default/Attention

Operating

logic

Step by step (port 3, port 4)

Step by step with Automatic closing

function. (Port 3, port 4)

Step by step (port 3, port 4)

Figure 16

Содержание ZK-SW400DC

Страница 1: ...for choosing our product Please read the instructions carefully before operation Follow these instructions to ensure that the product is functioning properly The images shown in this manual are for i...

Страница 2: ...the design and that the said personnel have received thorough training in operating and maintaining the machine unit equipment It is further essential for the safe operation of the machine unit equip...

Страница 3: ...hine unit equipment and such amendments shall not give any right to claim any compensation or damages under any circumstances ZKTeco shall in no way be responsible I in case the machine unit equipment...

Страница 4: ...biometric verification procedures and the productization of biometric verification SDK which was initially widely applied in PC security and identity authentication fields With the continuous enhance...

Страница 5: ...cription Button or key names for devices For example press OK Window names menu items data table and field names are inside square brackets For example pop up the New User window Multi level menus are...

Страница 6: ...LLATION STEPS 13 4 3 1 PREPARATION BEFORE MAIN MACHINE INSTALLATION 13 4 3 2 ACCESSORY INSTALLATION 13 4 3 3 MAIN MACHINE INSTALLATION 15 4 3 4 SIZE OF CONTROL BOX 18 4 3 5 LIMIT SWITCH ADJUSTMENT 18...

Страница 7: ...age of this product Please check if the leakage protection switch is installed and the grounding system is correct Please check if additional equipments or materials are required to meet the specific...

Страница 8: ...using and maintenance of this product must be carried out by professionals Children are not allowed be touch the control devices or remote transmitters A warning sign must be placed somewhere on the...

Страница 9: ...Parts List Parts List Standard Configuration No 1 Picture Name Quantity 1 Main Machine 2 2 Control Box 1 3 Manual Release Bar 1 4 Remote Control 2 5 Wall Bracket 4 6 Front Mounting Bracket 2 7 Connect...

Страница 10: ...opyright 2022 ZKTECO CO LTD All rights reserved 12 Limit Stopper 1 13 Spring Washer 12 2 14 Gasket 2 Parts List Optional No 1 Picture Name Quantity 1 Infrared Sensor 1 2 Wireless Keypad 1 3 Alarm Lamp...

Страница 11: ...ving Speed 22 to 26s 90 Max single leaf weight 400Kg Max single leaf length 3m Max piston stroke 45cm Max force 3000N Remote Control Distance 30m Remote Control Mode Single button mode Storage Battery...

Страница 12: ...measuring less than 3m in length To combine the screw rod transmission the drive mode uses the worm and worm gear For security purposes this gate opener must be put inside the enclosure or yard Instal...

Страница 13: ...t 2022 ZKTECO CO LTD All rights reserved Size of Main Machine and Mounting Bracket 4 2 1 Size of Main Machine 1450mm 1000mm 106mm 4 2 2 Size of Mounting Bracket Front mounting bracket Wall bracket 70m...

Страница 14: ...m above the ground and make sure that there are reliable fixed points for mounting brackets Cable bury Please use two PVC pipes to bury the motor and power cables as well as the control cables separat...

Страница 15: ...xternal accessories such as an electric lock infrared sensor alarm lamp or external button switch Increase the embedded cables accordingly do make sure the sectional diameter of the electric lock cabl...

Страница 16: ...ine and the connecting bracket with the installation screws and then manually adjust the telescopic arm to the appropriate length Finally fix the telescopic arm connector and the front mounting bracke...

Страница 17: ...have have a door door limit limit stopper stopper installed installed It It is is recommended recommended to to install install with with a safety safety stopper stopper should should be be prepared...

Страница 18: ...stopper installed installed It It is is recommended recommended to to install install with with a safety safety stopper stopper should should be be prepared prepared by by the the users users themsel...

Страница 19: ...LAR SOLAR 1 just 1 just a battery battery voltage voltage can can be be connected connected at at once once or or 12V 12V or or 24V 24V Out Out 24 12VDC 24 12VDC 250mA 250mA Electric Electric Lock Loc...

Страница 20: ...ure safety and protect the machines please install a gate stopper at the open limit position when the door opens outward to prevent the gate from running over its travel Meanwhile to enable the 2 swin...

Страница 21: ...K LOCK BLK BLK OUT OUT LPW LPW 24 24 12 12 COM COM SPD SPD PH PH STP STP STR STR PHS PHS EO EO EC EC 12 12 11 11 10 10 9 8 7 6 5 4 3 2 1 U1 U1 M2 M2 Transformer Transformer 240 22V 240 22V 120VA 120VA...

Страница 22: ...18 19 19 20 20 21 21 22 22 LOCK LOCK BLK BLK OUT OUT LPW LPW 24 24 12 12 COM COM SPD SPD PH PH STP STP STR STR PHS PHS EO EO EC EC 12 12 11 11 10 10 9 8 7 6 5 4 3 2 1 U1 U1 SOLAR SOLAR Terminal Remar...

Страница 23: ...inhibits opening During opening reverses motor direction for 1 second If not used left unconnected 9 Analog closing edge input 8K2 ohm Waiting for a closing command It inhibits closing During closing...

Страница 24: ...or 2 8A TR1 Slowing down speed trimmer TR2 Obstacle detection sensibility trimmer TS1 TS3 Buttons up down TS2 Enter button DSP Display FS3 FS4 Transformer input 12 20Vac 100 200VA F2 Battery fuse 10A...

Страница 25: ...e pause the display shows the seconds countdown to closing Travel Setting VERY IMPORTANT After the first time installation but before starting the normal operation one important step that you must tak...

Страница 26: ...n speed Do not set the speed to low less than 10 cm sec on the wing edge to avoid the gate stops in too cold conditions Obstacle sensibility trimmer fine tunes the obstacle detection level learned by...

Страница 27: ...button TS2 once for at least 1 second to enter the base menu is on the display with up down its possible to select other functions of this menu To exit this menu select or push up and down together A...

Страница 28: ...for a while if the operation is done To delete all codes select and push enter then confirm with Learning traveling Automatic learning procedure Same as 5 4 Manual learning procedure Attention before...

Страница 29: ...motor 2 close motor 2 Keep pushed TS2 to start the selected motor in Direct operation mode 5 7 2 Advance Menu At the Initial display push enter button till the display is shown With up down its possi...

Страница 30: ...closing time Electric lock activation time seconds 00 99 seconds 00 99 seconds 00 99 seconds 00 99 seconds 00 99 seconds 00 99 seconds 00 99 Single wing mode Disable Enable It works on motor 2 Disable...

Страница 31: ...g base menu Refer to Automatic transmitters learning Disable Low power mode Disable Enable Disable Kickback stroke mode Disable Enable In this menu you can enable the stroke at start to unlock the ele...

Страница 32: ...tance between the photocell receiver and emitter should not be less than 2 meters otherwise it will affect the induction of the photocell NO NO COM COM N C N C V V V V V V V V TS2 TS2 TS3 TS3 TS1 TS1...

Страница 33: ...charger charger Storage Storage battery battery TS2 TS2 TS3 TS3 TS1 TS1 S D S D SPEED SPEED OBSTD OBSTD U2 U2 I D 2 1 0 V 1 0 AC AC IN IN BATT BATT M1 M1 M2 M2 13 13 14 14 15 15 16 16 17 17 18 18 19 1...

Страница 34: ...er is off 2 Fuse is burned 3 Control board power wiring with the problem 1 Switch on the power supply 2 Check the fuse change it if it burns 3 Rewiring according to instructions The gate can open but...

Страница 35: ...t circuit Check wiring Remote control working distance is too short Signal is blocked Connect with an external antenna 1 5 meters above the ground The gate moves to the middle position then stop or re...

Страница 36: ...t 2022 ZKTECO CO LTD All rights reserved ZKTeco Industrial Park No 32 Industrial Road Tangxia Town Dongguan China Phone 86 769 82109991 Fax 86 755 89602394 www zkteco com Copyright 2022 ZKTECO CO LTD...

Отзывы: