SpeedFace-V5L Series
User Manual
P a g e
| 75
Copyright©2022 ZKTECO CO., LTD. All rights reserved.
Access Control Options
Tap
Access Control Options
on the
Access Control
interface to set the parameters of the control lock of
the terminal and related equipment.
Function Description
Function Name
Description
Gate Control Mode
It toggles between
ON
or
OFF
switch to get into gate control mode or not.
When set to
ON
, the interface removes the Door lock relay, Door sensor
relay, and Door sensor type options.
Door Lock Delay (s)
The length of time that the device controls the electric lock to be in unlock
state.
Valid value: 1~10 seconds; 0 seconds represents disabling the function.
Door Sensor Delay (s)
If the door is not locked and is left open for a certain duration (Door Sensor Delay),
an alarm will be triggered.
The valid value of Door Sensor Delay ranges from 1 to 255 seconds.
Door Sensor Type
There are three Sensor types:
None
,
Normal Open
,
and
Normal Closed
.
None:
It means the door sensor is not in use.
Normally Open:
It means the door is always left open when electric power is on.
Normally Closed:
It means the door is always left closed when electric power is
on.