RevFace15
User Manual
P a g e
| 69
Copyright©2023 ZKTECO CO., LTD. All rights reserved.
Door Sensor Type
There are three Sensor types:
None, Normal Open(NO),
and
Normal Closed(NC)
.
None:
It means the door sensor is not in use.
Normally Open(NO):
It means the door is always left open when electric power is
on.
Normally Closed(NC):
It means the door is always left closed when electric power
is on.
Verification Mode
The supported verification mode includes Password/Card/Face, User ID Only,
Password, Card Only, PCard, Password/Card, Face Only,
Face+Password, Face+Card.
Door Available Time
Period
It sets the timing for the door so that the door is accessible only during that
period.
Normal Open Time
Period
It is the scheduled time-period for “Normal Open” mode so that the door is
always open during this period.
Master Device
While configuring the master and slave devices, you may set the state of the
master as
Out
or
In
.
Out
: A record of verification on the master device is a check-out record.
In
: A record of verification on the master device is a check-in record.
Slave Device
While configuring the master and slave devices, you may set the state of the
slave as
Out
or
In
.
Out
: A record of verification on the slave device is a check-out record.
In
: A record of verification on the slave device is a check-in record.
Auxiliary Input
Configuration
Sets the door unlock time period and auxiliary output type of the auxiliary
terminal device.
Auxiliary output types include None, Trigger door open,
Trigger Alarm, Trigger door open and Alarm.
Verify Mode by
RS485
The verification mode is used when the device is used either as a host or
slave.
The supported verification mode includes Card only, and Card + Password.
Speaker Alarm
It transmits a sound alarm or disassembly alarm from the local. When the
door is closed or the verification is successful, the system cancels the alarm
from the local.
Reset Access Setting
The access control reset parameters include door lock delay, door sensor
delay, door sensor type, verification mode, door available time period, normal
open time period, master device, and alarm. However, erased access control
data in Data Mgt. is excluded.