RevFace15
User Manual
P a g e
| 70
Copyright©2023 ZKTECO CO., LTD. All rights reserved.
Time Attendance Terminal:
Function Description of Time Attendance Terminal:
Function Name
Description
Door Lock Delay (s)
The length of time that the device controls the electric lock to be in unlock
state.
Valid value: 1 to 10 seconds; 0 seconds represents disabling the function.
Door Sensor Delay (s)
If the door is not locked and is left open for a certain duration (Door Sensor Delay),
an alarm will be triggered.
The valid value of Door Sensor Delay ranges from 1 to 255 seconds.
Door Sensor Type
There are three Sensor types:
None, Normal Open(NO),
and
Normal Closed(NC)
.
None:
It means the door sensor is not in use.
Normally Open(NO):
It means the door is always left open when electric power is
on.
Normally Closed(NC):
It means the door is always left closed when electric power
is on.
Door Alarm Delay(s)
When the state of the door sensor is inconsistent with that of the door sensor type,
alarm will be triggered after a time period; this time period is the Door Alarm Delay
(the value ranges from 1 to 999 seconds).
Retry Times to Alarm
When the number of failed verification reaches the set value (value ranges from 1
to 9 times), the alarm will be triggered. If the set value is None, the alarm will not be
triggered after failed verification.