5
Outline dimensions of the control PCB: 181mm(length) × 106mm (width) for InBio160/260
Pro; 226mm (length) × 106mm (width) for InBio460 Pro.
External box dimensions: 350(L)mm × 300(W)mm × 90(H)mm.
Valve regulated lead-acid battery:
Constant voltage charge voltage regulation
Cycle use : 14.5V~14.9V(25)
Initial current: less than 2.88A1
Standby use: 13.6V~13.8V(25)
Capacity: 12V, 7.2Ah/20hr
Battery Type: LC-RA127R2T1
Battery Caution:
Do not charge in a gas tight container.
Do not short the battery terminals.
Do not incinerate.
Flush with water at once if contact is made with electrolyte (Acid).
Do not attempt to disassemble the battery.
Control Panel Indicators
2.3
When the InBio160/260/460 Pro is powered on, normally the POWER indicator (red) is lit constantly,
the RUN indicator (green) shall flash slowly (indicating the system is normal), and other indicators
are all off.
LINK indicator (green): indicates proper TCP/IP connection if it is lit constantly;
ACT indicator (yellow): indicates transmission of TCP/IP data if it flashes;
EXT RS485 (TX) indicator (yellow): indicates sending of 485 data if it flashes;
EXT RS485 (RX) indicator (green): indicates receiving of 485 data if it flashes;
CARD indicator (yellow): indicates input of Wiegand signal if it is lit.
Содержание InBio160
Страница 1: ...USER MANUAL Applicable Models InBio160 260 460 Pro Access Control Panel Version 1 0 ...
Страница 10: ...6 Indicator Diagram Figure 2 1 Indicators in the InBio460 Pro ...
Страница 13: ...9 Control Panel System Installation 3 3 Figure 3 2 Schematic Diagram of System Installation ...
Страница 15: ...11 InBio260 Pro Terminal connection diagram ...
Страница 16: ...12 InBio460 Pro Terminal connection diagram ...