InBio260 Pro Terminal connection diagram 

 

 

 

 

 

 

 

 

Содержание InBio160

Страница 1: ...USER MANUAL Applicable Models InBio160 260 460 Pro Access Control Panel Version 1 0 ...

Страница 2: ...ny or licensers possessing copyright Unless permitted by obligees no one can copy distribute modify extract decompile disassemble decode reverse engineer rent transfer sub license such software in any form or conduct other behaviors infringing software copyright exclusive of cases with prohibition of such limitation by applicable laws Due to product update our company does not promise the consiste...

Страница 3: ...cess Control Panel For the installation Please refer to Applicable Models InBio Pro Series Access Control Panels Installation Guide Not all the devices have the function with the real product prevails The pictures in this manual may not be exactly consistent with those of your purchased product the actual product s display shall prevail ...

Страница 4: ...ANEL CONNECTION TERMINALS 10 3 4 CONNECTION WITH DOOR SENSORS EXIT SWITCHES AUXILIARY INPUT DEVICES AND PC485 EXTENSION 3 5 COMMUNICATION 13 CONNECTION WITH READERS 16 3 6 RELAY OUTPUT CONNECTION 19 3 7 ACCESS CONTROL OPERATOR PANEL SYSTEM POWER SUPPLY STRUCTURE 21 3 8 4 EQUIPMENT COMMUNICATION 23 ACCESS CONTROL NETWORKING WIRES AND WIRING 23 4 1 TCP IP COMMUNICATION 24 4 2 RS485 COMMUNICATION 25 ...

Страница 5: ...he equipment by accidental contact of the exposed wires 6 Repair Do not attempt to have an unauthorized repair of the equipment Disassembly or detachment is risky and likely to cause shock All repairs should be done by a qualified technician 7 If any of the following cases arise disconnect the power supply from the equipment first and intimate the technician immediately The power cord or connector...

Страница 6: ...s frequently when the system is powered on Be sure to unplug the connection terminals before starting any relevant welding job 3 Do not detach or replace any control panel chip without permission and an unpermitted operation may cause damage to the control panel 4 It is recommended not to connect any other auxiliary devices without permission All non routine operations must be communicated to our ...

Страница 7: ...ock to release the self induced electromotive force during onsite connection for application of the access control system 12 It is recommended that an electronic lock and a control panel should use separate power supplies 13 It is recommended to use the power supply delivered with the system as the control panel power supply 14 In a place with substantial magnetic interference galvanized steel pip...

Страница 8: ...Use Ethernet and RS485 industrial bus dual communication technology for reliable communications Control Panel with a watchdog hardware built in to prevent a crash Over current over voltage and inverse voltage protection for the input of the power supply to the control panel Over current protection for the power supply to card readers Instant over voltage protection for all input output ports Insta...

Страница 9: ... with water at once if contact is made with electrolyte Acid Do not attempt to disassemble the battery Control Panel Indicators 2 3 When the InBio160 260 460 Pro is powered on normally the POWER indicator red is lit constantly the RUN indicator green shall flash slowly indicating the system is normal and other indicators are all off LINK indicator green indicates proper TCP IP connection if it is ...

Страница 10: ...6 Indicator Diagram Figure 2 1 Indicators in the InBio460 Pro ...

Страница 11: ...7 3 Installation and Connection Installation Procedure 3 1 Appearance and Internal of the panel box Installation steps for the control panel ...

Страница 12: ...the equipment The access control wires must be separated according to heavy and light current the control panel wires electronic lock wires and exit button wires must run through their casing pipes respectively Control Panel Door sensor Electronic lock Exit button Indoor wiegand card reader Outdoor wiegand card reader Ceiling Outdoor TCP IP Network communication wire Indoor 12V Power line RS485 Ne...

Страница 13: ...9 Control Panel System Installation 3 3 Figure 3 2 Schematic Diagram of System Installation ...

Страница 14: ...an be connected with up to 63 InBio Pro control operator panels preferably fewer than 32 The communication wires should be kept away from high voltage wires as far as possible and should be neither routed in parallel with nor bundled with power wires A management workstation is a PC connected with the network By running the access control management software installed in the PC access control mana...

Страница 15: ...11 InBio260 Pro Terminal connection diagram ...

Страница 16: ...12 InBio460 Pro Terminal connection diagram ...

Страница 17: ...d PC485 Extension Communication Door sensor A Door Sensor is used to sense the open close status of a door With a door sensor switch an access control panel can detect the unauthorized opening of a door and will trigger the output of alarm Moreover if a door is not closed within a specified period after it is opened the door control panel will also raise the alarm It is recommended to select two c...

Страница 18: ... wire and wrap it with insulating tape Make sure to avoid electromagnetic interference such as light switches and computers It is recommended to use two core wires with a gauge over 0 3mm2 as the connection wire between an exit switch and the Control panel Auxiliary input TheInBio160 Pro provides one auxiliary input interface the InBio260 Pro provides two and theInBio460 Pro provides four which ma...

Страница 19: ...Bio460 Pro and EX0808 through PC485 NOTE 1 A maximum of eight EX0808 extended boards can be connected to an inBio460 Pro controller 2 Each EX0808 can connect a maximum of eight auxiliary input devices and eight auxiliary output devices 3 A separate power supply is required for each EX0808 4 Set the RS485 OSDP addresses of each EX0808 by the DIP switch before power is supplied DIP Switch Setting fo...

Страница 20: ...n Set the RS485 address device number of the reader by DIP switch or other ways Figure 3 5 Connection between inBio460 Pro and RS485 Readers The QR50 code reader does not need to be connected to the lock body when it is used as a reader The controller in the figure only lists some of the wirings and there are many kinds of connections between the machines RS485 common connection reference as shown...

Страница 21: ...ares the power supply with the device it is recommended that the connection between the EXT RS485 port and the reader be no longer than 100m Otherwise it is recommended that using a separate power supply for the reader For some of the devices with much greater consumption we suggest to use the separately power supplies to make sure the steady operation Connection with Wiegand Readers The InBio160 ...

Страница 22: ...etween the Control Panel and Wiegand Readers Wiegand common connection reference as shown below NOTE For more detailed information on the use of QR50 such as connection and software configuration please refer to the QR50 user manual ...

Страница 23: ...ontrol panel provides multiple electronic lock outputs The COM and NO terminals apply to the locks that are unlocked when power is connected and locked when power is disconnected The COM and NC terminals use the locks that are locked when power is connected and unlocked when power is disconnected 3 To protect the access control system against the self induced electromotive force generated by an el...

Страница 24: ...ro as an example here as shown in the following figure Figure 3 7 Dry mode wiring diagram of lock connecting with external power supply recommend Figure 3 8 Wet mode wiring diagram of lock and controller common power supply ...

Страница 25: ...21 Access Control Operator Panel System Power Supply Structure 3 8 An access control operator panel is powered by 12V DC Generally to reduce power interference ...

Страница 26: ...uld be powered respectively To prevent power failure of a control operator panel from making the whole system unable to work normally the access control management system is usually required to have one UPS at least and access control locks are powered externally to guarantee the access control management system can still work normally during power failure ...

Страница 27: ... If parallel wiring is unavoidable for environmental reasons the distance must be above 50cm Try to avoid using any conductor with a connector during distribution When a connector is indispensable it must be crimped or welded No mechanical force can be applied to the joint or branch of conductors In a building the distribution lines must be installed horizontally or vertically They should be prote...

Страница 28: ...eliably and linked to ground wires through large diameter cables The impedance of this section of wire cannot exceed 2 ohms Also the shielding layer must be connected reliably and grounded at one end to guarantee a uniform current direction The ground wire of the shielding layer must be connected through a large diameter wire not less than 2 5mm2 TCP IP Communication 4 2 The Ethernet 10 100Base T ...

Страница 29: ... but preferably should be connected with less than 32 3 To eliminate signal attenuation in communication cables and suppress interference if the bus is longer than 300 meters one 120ohm resistance is usually inserted between the first and last access control operator panels on the RS485 bus 4 For this access control operator panel putting place 8 of the DIP switch to the ON position is equivalent ...

Страница 30: ...ut places 1 2 3 and 6 to the ON position as illustrated below 485 address setting table Place Address Switch Setting 1 2 3 4 5 6 Address No 1 2 4 8 16 32 01 ON OFF OFF OFF OFF OFF 02 OFF ON OFF OFF OFF OFF 03 ON ON OFF OFF OFF OFF 04 OFF OFF ON OFF OFF OFF 05 ON OFF ON OFF OFF OFF 06 OFF ON ON OFF OFF OFF 07 ON ON ON OFF OFF OFF 08 OFF OFF OFF ON OFF OFF 09 ON OFF OFF ON OFF OFF 10 OFF ON OFF ON O...

Страница 31: ...N 39 ON ON ON OFF OFF ON 40 OFF OFF OFF ON OFF ON 41 ON OFF OFF ON OFF ON 42 OFF ON OFF ON OFF ON 43 ON ON OFF ON OFF ON 44 OFF OFF ON ON OFF ON 45 ON OFF ON ON OFF ON 46 OFF ON ON ON OFF ON 47 ON ON ON ON OFF ON 48 OFF OFF OFF OFF ON ON 49 ON OFF OFF OFF ON ON 50 OFF ON OFF OFF ON ON 51 ON ON OFF OFF ON ON 52 OFF OFF ON OFF ON ON 53 ON OFF ON OFF ON ON 54 OFF ON ON OFF ON ON 55 ON ON ON OFF ON ON...

Страница 32: ... 485 ZKPanelWeb 4 5 To help users conveniently manage controllers the built in Web Server function is added to some models With this function a user can connect to the controller through a PC and enter the IP address of the controller to access the web Users can also use the Web Server function to perform other operations such as network configuration Push communication configuration time synchron...

Страница 33: ...address of the controller could be found by searching devices with the BioSecurity software Access Access Device Device Search Device Basic Operation Bar of the Web Server Change of the Administrator s Password 1 Click The following page is displayed 2 Enter the old and new passwords and click Confirm to change the administrator s login password ...

Страница 34: ... and click Confirm Use Conditions of the Server Click and you can view the version of the current server as well as thebrowser and resolution recommended for the server Online Help of the Server If you met some problems when using the server click to view or download the user help document ...

Страница 35: ...k and then click Confirm to return to the server login page Network Settings TCP IP Settings Function introduction Set the TCP IP communication parameters which are used in the communications between device and PC ...

Страница 36: ...d you can modify it according to the actual Primary DNS the default value is null and you can set its value 3 Click Confirm to write parameters into the device please restart the device by manual Communication Settings PUSH Server Settings PUSH Server Indicates that the controller proactively pushes information to the server IP Mode the default server IP is 0 0 0 0 and you can modify it according ...

Страница 37: ...Communication Password Communication Password Indicates that network communication is encrypted The default value is null and you can set its value If you configure the communication password here the same communication password must be configured on the server before the connection can be set up System User Settings Click Edit to change the login password of an administrator or a user ...

Страница 38: ... You can manually configure the controller time or synchronize the controller time with the PC time and click Confirm to complete the setting System Settings Click Reboot The device will be restarted Device Information ...

Страница 39: ...he device by searching The process is as follows 1 Click Access Device Search to open the Search interface in the software 2 Click Search and it will prompt Searching 3 After searching the list and total number of access controllers will be displayed 4 Click Add in operation column a new window will pop up Select Icon type Area and Add to Level from each dropdown and click OK to add the device 4 6...

Страница 40: ... given below 1 In System Basic Management Parameters set Enable QR Code to Yes and select the QR code status according to the actual situation The default is Dynamic the valid time of the QR code can be set 2 On the Server choose System Authority Management Client Register to add a registered App client ...

Страница 41: ...ccessfully set the Client Name and tap Connection Test 5 After the network is connected successfully tap Save The Mobile Credential function is only valid when logging in as an employee tap on Employee to switch to Employee Login screen Enter the Employee ID and Password Default 123456 to login 6 Tap Mobile Credential on the App and a QR code will appear which includes employee ID and card number ...

Страница 42: ...hen using this function for the first time the App will prompt to authorize the modification of screen brightness settings as shown in the figure The QR code is automatically refreshed for every 30s and it also supports manual refresh NOTE For other specific operations please refer to ZKBioSecurity Mobile App User Manual ...

Страница 43: ...l be saved on the device according to the device type you have selected to verify the unique similarity between you and the User ID you have registered You can optionally enter your Name and Code The above information is necessary for you to use our products If you do not provide such information you cannot use some features of the product regularly 2 Product information According to the product m...

Страница 44: ...l know that some data cannot be downloaded for sake of data security 6 All the personal information in our products can be queried modified or deleted If you no longer use our products please clear your personal data III How we handle personal information of minors Our products website and services are mainly designed for adults Without consent of parents or guardians minors shall not create their...

Страница 45: ...ement Lead Pb Mercury Hg Cadmium Cd Hexavalen t chromium Cr6 Polybrominate d Biphenyls PBB Polybrominated Diphenyl Ethers PBDE Chip Resistor Chip Capacitor Chip Inductor Diode ESD component Buzzer Adapter Screws indicates that the total amount of toxic content in all the homogeneous materials is below the limit as specified in SJ T 11363 2006 indicates that the total amount of toxic content in all...

Страница 46: ...42 Copyright 2021 ZKTECO CO LTD All Rights Reserved ZK Building Wuhe Road Gangtou Bantian Buji Town Longgang District Shenzhen China 518129 Tel 86 755 89602345 Fax 86 755 89602394 www zkteco com ...