16
Connection with Readers
3.6
The Control panel supports RS485 reader and Wiegand reader.
Connection with RS485 readers
The InBio160 Pro can connect two RS485 readers in the one-door two-way mode. The InBio260 Pro
provides four readers, which can be connected in the two-door two-way mode. The InBio460 Pro
provides four readers, which can be connected in the two-door two-way or four-door two-way
mode.
RS485 reader connection: Set the RS485 address (device number) of the reader by DIP switch or
other ways.
Figure 3-5
Connection between inBio460 Pro and RS485 Readers
The QR50 code reader does not need to be connected to the lock body when it is used as a reader.
The controller in the figure only lists some of the wirings, and there are many kinds of connections
between the machines. RS485 common connection reference as shown below:
RS485
address
Control Panel
1
2
3
4
5
6
7
8
InBio160 Pro
#1Door
IN
#1Door
OUT
InBio260 Pro
#1Door
IN
#1Door
OUT
#2Door
IN
#2Door
OUT
InBio460 Pro
#1Door
IN
#1Door
OUT
#2Door
IN
#2Door
OUT
#3Door
IN
#3Door
OUT
#4Door
IN
#5Door
OUT
Содержание InBio160