06EXXX
Boom Arm Closing Brake Stroke
The larger the number, the longer the
deceleration time and the more stable the
boom arm operation. The Boom Arm
Closing Deceleration Distance value can be
set between 10 to 25 and the default value
is 20.
06E020
06E024
06E024
06E025
07EXXX
Boom Arm Closing Brake Speed
The smaller the number is, the faster the
deceleration, valid value: 2 to 30.
07E028
07E028
07E028
07E030
08EXXX
Force Adjustment
The larger the number, the greater the
efficiency of the boom arm opening and
closing force, valid value: 5 to 50.
08E005
08E005
08E005
08E005
09EXXX
Close Limit Adjustment
Press [+/-] to adjust the position according
to the situation and press [Menu/save ] to
save, which can be set between 1 to 60.
09E005
09E005
09E005
09E016
10EXXX
Open Limit Adjustment
Press [+/-] to adjust the position according
to the situation and press [Menu/save ] to
save, which can be set between 1 to 60.
10E005
10E005
10E005
10E020
11EXXX
Automatic Closing Time for Unmanned
Passage
Set the time to automatically close the boo
m arm after successful verification but no o
ne passes, the larger the number, the longe
r
it takes to close the boom arm, valid value:
5 to 60.
11E000
11E000
11E000
11E000
12EXXX
Boom Arm Opening Memory
12E000: Close
12E001: Open
When more than two legal access signals
are given at the same time (including the
same direction and the opposite direction),
the system will remember all pass requests
and complete each pass in turn.
12E000
12E000
12E000
12E000
13EXXX
Core Component Position
13E000: Right
13E001: Left
13E000
or
13E001
13E000
or
13E001
13E000
or
13E001
13E000
or
13E001