Direction Interchange of the Boom Arm 

The operation steps are as follows: 

 

1.

 

Before operation, please turn off the power. Remove the spring, spring hanging arm and boom. 

2.

 

Replace the new direction of the spindle Connecting Arm. 

3.

 

Change the linkage Arm. 

4.

 

Turn the Limited Block to the other direction. 

5.

 

After the mechanical operation, you need to set the movement parameter 13E Core Component 
Position on the motherboard, such as changing from L to R, the value of this parameter should be 
set from 1 to 0, or set the direction of the movement on the app. 

 

Spring Adjustment 

If  the  boom  arm  shakes  when  it  rises,  you  can  adjust  the  spring  loosely, and  if  the  boom  arm  shakes 
when it falls, you can adjust the spring tightly. 

Содержание BG2000 Series

Страница 1: ... choosing our product Please read the instructions carefully before operation Follow these instructions to ensure that the product is functioning properly The images shown in this manual are for illustrative purposes only www zkteco in User Manual BG2000 Series Barrier Gate APP Version Date June 2022 Doc Version 1 1 English ...

Страница 2: ...fully familiar with the design and that the said personnel have received thorough training in operating and maintaining the machine unit equipment It is further essential for the safe operation of the machine unit equipment that personnel has read understood and followed the safety instructions contained in the manual In case of any conflict between terms and conditions of this manual and the cont...

Страница 3: ...chine unit equipment and such amendments shall not give any right to claim any compensation or damages under any circumstances ZKTeco shall in no way be responsible i in case the machine unit equipment malfunctions due to any non compliance of the instructions contained in this manual ii in case of operation of the machine unit equipment beyond the rate limits iii in case of operation of the machi...

Страница 4: ...fication procedures and the productization of biometric verification SDK which was initially widely applied in PC security and identity authentication fields With the continuous enhancement of the development and plenty of market applications the team has gradually constructed an identity authentication ecosystem and smart security ecosystem which are based on biometric verification techniques Wit...

Страница 5: ...onvention Description Button or key names for devices For example press OK Window names menu items data table and field names are inside square brackets For example pop up the New User window Multi level menus are separated by forwarding slashes For example File Create Folder Symbols Convention Description This represents a note that needs to pay more attention to The general information which hel...

Страница 6: ...ION WITH LPR CAMERA 12 CONNECTION WITH UHF SYSTEM 13 CONNECTION WITH LOOP DETECTOR 14 CONNECTION WITH VR10 RADAR SENSOR 15 CONNECTION WITH INFRARED PHOTOCELL DETECTOR 16 CONNECTION WITH DEVICE S WI FI 18 8 FUNCTIONAL PARAMETER SETTINGS 20 MAINBOARD PARAMETER SETTINGS 20 8 1 1 OPERATING PROCEDURE 20 PARAMETER SETTINGS DESCRIPTION 21 ERROR CODE 24 REMOTE CONTROL PAIRING AND UNPAIRING SUPPORT SETTING...

Страница 7: ...nual P a g e 6 Copyright 2022 ZKTECO CO LTD All rights reserved DIRECTION INTERCHANGE OF THE BOOM ARM 28 SPRING ADJUSTMENT 28 10 PRODUCT PACKING LIST 29 11 TROUBLESHOOTING 30 12 SAFETY PRECAUTIONS 32 13 TRANSPORTATION AND STORAGE 32 14 WARRANTY 32 ...

Страница 8: ...ation comprehensive performance and so on It can be used in real time application areas such as offices hospitals public places residential areas to ease traffic issues 2 Features and Functionalities Support ZKBarrier APP control Reversible left and right directions Embedded programmable controller with Wi Fi communication module Interactive and stylish chassis LED design DC 24V brushless motor wi...

Страница 9: ...Chassis Dimension L W H 350 306 1070mm Chassis Weight 45kg Motor Type 24V DC brushless motor Motor MCBF 5 million times Output Power 100W Rated Current 5A Power Supply Input AC110V 220V 10 50 60Hz Output DC24V 10A Remote Control Distance Operating Temperature 30 C to 75 C Operating Humidity 90 Chassis Housing Material Powder coated cold rolled sheet Protection level IP54 Duty Cycle 100 Motor Rated...

Страница 10: ... Version User Manual P a g e 9 Copyright 2022 ZKTECO CO LTD All rights reserved 4 Appearance and Dimensions 5 Left and Right Directions L The chassis on the left the boom on the right R The chassis on the right the boom on the left ...

Страница 11: ...mportant to set the spring balance again to achieve a new balance The bottom of the spring contains two plastic nuts designed to adjust the new balance When powered on do not change the wire connection inside Connect the GND to the cabinet for ensured protection Cable Embedding 1 a cable are required 2 The route cables must pass through the protective sleeves 3 Use a tool to open the cable tray on...

Страница 12: ... the test If the barrier boom arm is not installed please adjust and remove the spring under the guidance of a professional If the length of the barrier boom arm is cut and adjusted the tightness of the spring and the spring quantity need to be adjusted accordingly to avoid the abnormal working status that cannot drop the boom During the installation of the boom damage to the metal surface should ...

Страница 13: ...ights reserved 7 Mainboard Wiring Instructions Please disconnect the power supply before wiring Check carefully whether the terminals are tightened and whether the wiring is firm Wire Connection of the New Mainboard Wiring diagram of new control board of the app version Connection with LPR Camera ...

Страница 14: ...d Confirm Barrier Gate Connection with LPR Device Installtion Based on the project site planning confirm the installation positions of exits and entrances and then install the wiring Connection with UHF System Note The Reader1 and 2 of Inbio260 Controller corresponds to LOCK1 Reader3 and 4 corresponds to LOCK2 ...

Страница 15: ...talltion Based on the project site planning confirm the installation positions of exits and entrances and then install the wiring Connection with Loop Detector Anti smash and Auto close Function Coil Circumference Coil Number 3m Based on requirements ensure that the inductance is between 3m to 6m 5 to 6 turns 6m to 10m 4 to 5 turns 10m to 25m 3 turns 25m 2 turns ...

Страница 16: ...2022 ZKTECO CO LTD All rights reserved Confirm Loop Coil Install Position Base on the type of lane such as car lane type or motorcycle lane type to onfirm the length and width of the loop coil installation Connection with VR10 Radar Sensor Anti smash and Auto close Function ...

Страница 17: ...reserved Confirm Radar Mounting Holes The installation hole of the radar is between 200 to 300mm from the inside of the straight boom and 650 to 800mm from the driveway ground non cement pier the installation position is shown in the figure Connection with Infrared Photocell Detector Anti smash Function ...

Страница 18: ...Version User Manual P a g e 17 Copyright 2022 ZKTECO CO LTD All rights reserved Anti smash and Auto close Function Confirm Photocell Detector Installtion Note that the transmitter and receiver are install at the same parallel angles ...

Страница 19: ...ollows 1 Open the ZKBarrier APP click Wi Fi Connection and then enter the connection page 2 You can choose either Manual Connection or Scan to Connect here take Manual Connection as an example click Manual Connection select the ZKBarrier XXXXXX Wi Fi name of the corresponding device and then enter the default password 1234567890 Note For security reasons it is recommended that you change the Wi Fi...

Страница 20: ...BG2000 Series Barrier Gate APP Version User Manual P a g e 19 Copyright 2022 ZKTECO CO LTD All rights reserved ...

Страница 21: ...nstallation and first power on you must use the Open and Close buttons on the mainboard to complete the self check process and learn the description of the menu Mainboard Parameter Settings Menu Save Menu options Confirm and Save Stop Stop the boom arm Flip down the parameter Open Increase parameter value Close Decrease parameter value 8 1 1 Operating Procedure ...

Страница 22: ...0 01E000 02EXXX Boom Arm Opening Speed 02E000 Low 02E001 Medium 02E002 Fast 02E003 Very Fast Adjust the corresponding speed according to the boom arm length 02E003 02E003 02E003 02E001 03EXXX Boom Arm Opening Brake Stroke The larger the number the longer the deceleration time and the more stable the boom arm operation The Boom Arm Opening Deceleration Distance can be set between 10 to 25 and the d...

Страница 23: ...g to the situation and press Menu save to save which can be set between 1 to 60 09E005 09E005 09E005 09E016 10EXXX Open Limit Adjustment Press to adjust the position according to the situation and press Menu save to save which can be set between 1 to 60 10E005 10E005 10E005 10E020 11EXXX Automatic Closing Time for Unmanned Passage Set the time to automatically close the boo m arm after successful ...

Страница 24: ...X RS485 Address 16E000 16E000 16E000 16E000 17EXXX Ground Sense Delay Time Setting Set the ground sense delay time by press button the larger the number set the longer the delay time the valid value is 0 to 251 17E000 17E000 17E000 17E000 18EXXX Core Component Type 18E000 20A to 0 6S 18E001 18B to 1 2S 18E002 18B to 2 5S Please set the parameters according to the core component 18E000 18E000 18E00...

Страница 25: ...000 23E000 23E000 23E000 24EXXX Remote Control Type 24E000 433MHz frequency 24E001 430MHz frequency 24E000 24E000 24E000 24E000 Error Code Erro Code Description Solve EL0002 Power on Self test failure Hall limit detection error Check the spring and boom arm blance EL0004 Run Timeout Restart the machine EL0008 Clutch Locked Check the 20E parameter EL016 The code disk detection failed Check the moto...

Страница 26: ...he parameter value to 15E200 Press Menu save to save the setting and that all the remote controls have been deleted Set Delay for Automatic Closing after Opening the Boom Arm Support setting on the ZKBarrier APP Long press the Menu save button then press Stop flip down to 11EXXX parameter and then press the to set the parameter value after selection Set the delay value as per the requirements Fina...

Страница 27: ...Please do not adjust them without the guidance of professionals to avoid mechanical damage Adjust the Horizontal Position of the Boom Arm The connecting boom crank will be an overlapping structure with the connecting boom arm s two rotation points coincident with the reducer s output shaft at three points and a line The boom arm is in this position horizontally If the boom arm is not level or incl...

Страница 28: ...cting boom arm crank is in an unfolded shape and the connecting boom arm s two rotation points and the reducer s output shaft are in an unfolded 3 point line This is the boom arm s vertical position If the boom arm is not in the vertical position and is inclined unscrew the two screws on the rocker spindle connecting arm rotate the boom arm to the vertical and tighten the screws Boom Arm Boom Arm ...

Страница 29: ... spindle Connecting Arm 3 Change the linkage Arm 4 Turn the Limited Block to the other direction 5 After the mechanical operation you need to set the movement parameter 13E Core Component Position on the motherboard such as changing from L to R the value of this parameter should be set from 1 to 0 or set the direction of the movement on the app Spring Adjustment If the boom arm shakes when it rise...

Страница 30: ...diameter is adapted to different boom lengths Boom length Spring size and quantity Spring Color logo 1 5m No need 2m 3 5mm 1 Blue 3 5mm 3m 3 5mm 1 4 0mm 1 Blue 3 5mm Green 4 0mm 4m 4 0mm 1 4 5mm 1 Green 4 0mm Yellow 4 5mm 10 Product Packing List Material Quantity Chassis Explosion Screw 4 Keys 2 Barrier Boom 1 Chassis Pressure Plate 4 Wireless Remote 2 Barrier Boom hexagon bolt 1 Machine 1 ...

Страница 31: ...ut is normal but the power indicator is off Cause 1 The power fuse might be blown 2 Abnormal power supply 3 Loose wiring Solution 1 Replace the fuse 2 Replace the power supply 3 Tighten the wiring Description The power indicator is on the landing boom indicator is normal and the motor is not running Cause 1 The motor wiring might be wrongly connected or the wiring is loose 2 The internal encoder o...

Страница 32: ...te control frequency is not matched or the receiver is damaged Solution 1 Replace the battery 2 Use manual button control 3 Use in open areas 4 Replace the remote control to re match or replace the receiver Description When the boom is closed halfway it bounces back to the open state Cause 1 The barrier boom might not be installed 2 The spring is too tight or the length of the barrier boom is chan...

Страница 33: ... any damage 13 Transportation and Storage When loading and unloading the product handle it with care During transportation and storage place it in a dry and corrosive free environment The product should be protected from moisture rain sun and corrosion 14 Warranty This product promises a warranty period of 2 years Upon normal use of the product damages are covered by the warranty However damages c...