Use screwdriver to dismantle the screws 
under the upward bracket. 

Close 

over

Glass frame

Use screws to fix the cover and the 
L- bracket to the main frame.

Glass frame

Clamp the lock and the U- bracket 
upwards to the corresponding position. 
Then use the screwdriver to fix it.

Glass frame

After assembling, the effect is as shown 
in Fig. 6.

Upper bracket

Down bracket

Glass frame

Glass door

Model

Position

Length

Width

Height

Diagram of Electric Bolt Lock Upward Bracket Installation Procedures

Diagram of Electric Bolt Lock Downward Bracket Installation Procedures

 Use screwdriver to dismantle 

he screws. Then dismantle 

covers on both sides. 

Close over

Close over

Glass door

Assemble the dismantled 
accessory (cover) and then 
assemble it together with the 
U- bracket.

Fix it with screws. 

Gusset plate 

Glass door

Upper bracket

Down bracket

Glass door

Glass door

Glass frame

Model

Position

Length

Width

Height

Close over

Glass door

After assembling, the effect is as 
shown in Fig. 6.

Glass door

The U- bracket clamps upwards 
the glass frame according to 
thickness (use spacer) of the 
glass door. After correction of 
the position, fix it on the glass 
frame.

Note: In case both the upside and downside parts 
are frameless glass, the distance between glass 
door and doorframe shall not be less than 7mm;
In case only one part is frameless glass, the 
distance between glass door and doorframe shall 
not be less than 4mm;

Wire 
outlet

Spacer

U- shape mouth

Lock

Decoration plate

Install spacer for downward 
U- bracket. Adjust the position 
and then fix it on the glass door 
with screws.

Fix the magnetic buckling 
plate on the bracket with 
screws.

Note: 

In case both the upside and downside parts are 

frameless glass, the distance between glass door and 
doorframe shall not be less than 7mm;In case only one 
part is frameless glass, the distance between glass door 
and doorframe shall not be less than 4mm;

Electric Strike Series

Magnetic Lock Series

El ect ric Bolt  Lock  ser ies

Brackets and Accessories

Me cha ni cal Lo ck Se riess

El ec tron ic Lo ck Se ries

Electric Strike Series

Magnetic Lock Series

El ect ric Bolt  Lock  ser ies

Brackets and Accessories

Me cha ni cal Lo ck Se riess

El ec tron ic Lo ck Se ries

AL-200PZ

AL-100PF

Содержание AL-100

Страница 1: ...eration o Door Opening 90 and available for load of 250kg Electrical Property Users can select appropriate products with different models and functions based on the following table Customization is available according to users requirements 12V 15 Model Voltage DC Current mA AL 130NO AL 130NC 240 120 Mechanical Lock 3 3 5mm 1mm AL 130 Series Electric Strike Installation Drawing Electric strikes Ele...

Страница 2: ... Opening 90 and available for load of 400kg Electrical Property Users can select appropri ate products with different models and functions based on the following table Customization is available acco rding to users requirements 12V 15 Model Voltage DC Current mA Unlock Method AL 131NO 240 3 3 5mm 1mm Door Frame Electric strikes Electric strikes 150 135 100 32 48 5 28 3 44 5 AL 131NO AL 131NC NC GN...

Страница 3: ...kg Electrical Property Users can select appropri ate products with different models and functions based on the following table Customization is available acco rding to users requirements Wiring 1 One diode is an accessory provided in the accessory bag The diode is used to prevent bounce back current and voltage produced during locking or unlocking from affecting the access control mainframe Users ...

Страница 4: ...r with anode mechanical lock or ball lock in office buildings wooden doors stainless steel doors fire doors and entrance gate of residence community Product Advantage Recessed type installation pleasant looking appearance wide lock mouth and more extensive application The electromagnetic part adopts high quality magnetic materials and special processi ng workm anship to ensure normal use and no re...

Страница 5: ...blue wire refer to COM common wire NC normal close and NO normal open respectively The purple wire and orange wire output NC normal close lock signals Limited current of lock status signal is 300mA when the input voltage is 12VDC Overload is forbidden Locking and unlocking status can be monitored after it is connected to the central control room Remark can be customized Se e Diagram 1 AL 100 Door ...

Страница 6: ... Fix the lock and the decoration plate on the doorframe based on the holes Step 5 Decide the center line according to the door electric bolt lock and the bolt Then stick the perforated paper to the door Step 6 Use special drilling tool to drill holes on relevant type of magnetic buckling plate according to corresponding electric bolt lock Step 7 Fix the magnetic buckling plate on the door with scr...

Страница 7: ...6X25X48 380 760 500 250 1000 500 500 250 700 350 1000 500 253X28X55 506X28X55 280X38 5X70 AL 350 LED AL 350D LED AL 500 LED 24V 10 AL 180M 198X21X35 380 12V 10 Model Dimensions mm Voltage DC Curr ent mA Indicator Lamp Signal Output NC NO AL 350 LED 10 During installation of this product offset toward right left upside and downside of center position of both the adsorption plate and the lock shall ...

Страница 8: ... A1 166 253 253 280 D Sucking Disk H L Sucking Disk T sucking Disk Series Model Dimension Identification Electric Strike Series Magnetic Lock Series Elect ric Bolt Lock ser ies Brackets and Accessories Mechanical Lock Seriess Electronic Lock Series Electric Strike Series Magnetic Lock Series Elect ric Bolt Lock ser ies Brackets and Accessories Mechanical Lock Seriess Electronic Lock Series Push in...

Страница 9: ... rotate direction Diagram Diagram Diagram Outside Inside The sign refer to rotate direction Outside Inside Outside Inside Inside Outside Door Z bracket L bracket Outside Inside Door frame L bracket Lock body Armature plate rubber ring Z bracket Diagram of Magnetic Lock Auxiliary Bracket Installation Procedures Inward opening Door AL 180PL AL 280PL AL 350PL AL 500PL AL 500DPL AL 180PZ AL 280PZ AL 3...

Страница 10: ...ame Install the tamper screw Door frame Door frame Glass door Glass door Glass door Small metal plate for height adjustment Screw Outside Inside Step 7 Use screws to fix the sub plate and the U bracket Their positions shall be consistent Make sure the rubber ring is installed during installation AL 180PU Step 8 Installation effect Electric Strike Series Magnetic Lock Series Elect ric Bolt Lock ser...

Страница 11: ...wn in Fig 6 Glass door The U bracket clamps upwards the glass frame according to thickness use spacer of the glass door After correction of the position fix it on the glass frame Note In case both the upside and downside parts are frameless glass the distance between glass door and doorframe shall not be less than 7mm In case only one part is frameless glass the distance between glass door and doo...

Отзывы: