background image

Electric Bolt Lock User Manual

Applicable Range: 

This lock is applicable for office buildings and frame door at the entrance of residence community. 

Product Advantage: 

Recessed type installation and pleasant-looking appearance. The electromagnetic part adopts high-quality magnetic 

                                   materials and special processing workmanship to ensure no residual magnetism even after long time operation. This 
                                   lock was designed and manufactured based on electronic, mechanical and mechanics principle to realize low-current 
                                   operation and reduce rate of failure and maintenance. Auxiliary bracket can be used for installation of frameless glass 
                                   door. 

Door Opening:  

180 and available for load of 1000kg. 

Electrical Property and others:

 Users can select suitable products with different models and functions based on the following table. 

                                                     Customization is available according to users' requirements.

A L - 1 0 0

A L - 3 0 0

2 0 0 X 3 5 X 3 8

2 0 0 X 3 5 X 3 8

350

350

1 2 V  1 5 %

Model

Lock size 

(mm)

Voltage (DC)

Current (mA)

Start-up

Wo rking

UnLock mo de

Yes

Door   

signal 

Delay function

Adjustable at 0, 3, 6, 9  
seconds 

Wiring

: 1. 

Power source: 

Red wire is the positive (+) input end of the lock power source and shall be connected to positive end. Black wire is 

             the negative (-) input end of the lock power source and shall be connected to negative end of the power source (12VDC). 
2. 

Door signal (conventional 2 wires configuration upon delivery): 

Two white wires are used for door status signal [NO (normal open) 

             indicates door opening status] output end. Limited current of door status signal is 300mA when the input voltage is 12VDC. Overload 
             is forbidden. Door opening and closing status can be monitored after it is connected to the central control room. 
3. The indicator lamp indicates working status of the electric lock and turns red after connected to power. 

Door signal (nonconventional 3 wires configuration, customized): 

When the door is under the opening status, the green wire, blue wire 

             and orange wire refer to COM (common wire), NC (normal close) and NO (normal open) respectively. Limited current of door status 
             signal is 300mA when the input voltage is 12VDC. Overload is forbidden. Door opening and closing status can be monitored after it is 
             connected to the central control room. 

Lock signal (conventional 2 wires configuration upon delivery):

 When the door is under the opening status, the purple wire and light 

             blue wire output NO (normal open) lock signals. The purple wire and orange wire output NC (normal close) lock signals.  In case of 
             2-wire signal output (select only one between NO and NC), limited current of lock status signal is 300mA when the input voltage is 
             12VDC. Overload is forbidden. Locking and unlocking status can be monitored after it is connected to the central control room.

 

Lock signal (nonconventional 3 wires configuration, customized):

 When the door is under the opening status, the purple wire, orange 

             wire and light blue wire refer to COM (common wire), NC (normal close) and NO (normal open) respectively. The purple wire and 
             orange wire output NC (normal close) lock signals. Limited current of lock status signal is 300mA when the input voltage is 12VDC. 
            Overload is forbidden. Locking and unlocking status can be monitored after it is connected to the central control room.
Remark: 

①②③

can be customized. 

(Se e Diag ram  1)

AL-100

Door siganl

+

-

( Diagram only for reference )

Permanent magnet

Magnetic induction field

+

-

+

-

NC

GND

NO

PUSH

12V

GND

GND

12V

-

+

UPS

Control

NC NO

COM

NC

GND

NO

PUSH

12V

GND

GND

12V

-

+

UPS

Control

NC NO

COM

+

-

AL-300

Unlock by 

disconneting power

1 2 V  1 5 %

Yes

Electric Bolt Lock

Gusset Plate

Cover metal Plate

Wood Sctew

              Machine Screw

Manucal

1

2

4

5

Number

Item

Unit

PC

6

Number

Applicable Range

1

2

        The distance between glass door 

and door frame can not less than 7mm 

on frameless door.The distance 

between glass door and door frame 

can not less than 4mm on unilateral 

frameless door.

For upper frameless 

glass door

1

1

1

5

5

1

3

1

AL-300

L 2 0 0 X W 3 5 X H 3 8

M4X21

M5

×

10

L 1 0 0

W 3 0

H 1 5

X

X

L 2 1 0

W 4 0

H 1

X

X

AL-100    

AL-100PF     

AL-200PZ    

AL-100PF     

AL-200PZ    

ELECTRIC  LOCKS

Specification

Fittings

Installation

Certificate

PC

PC

PC

PC

/

/

Applicable to the fixed door lock, 

gusset plate.

Fixed for metal doors, 

gusset plate.

Series

Bracket

Upper Bracket

Down Bracket

Side mount bracket for hollow frame

For down frameless 

glass door

For hollow door or 

hollow frame

Gusset plate

Standard packing list

Component

Electric Strike Series

Magnetic Lock Series

El ect ric Bolt  Lock  ser ies

Brackets and Accessories

Me cha ni cal Lo ck Se riess

El ec tron ic Lo ck Se ries

Electric Strike Series

Magnetic Lock Series

El ect ric Bolt  Lock  ser ies

Brackets and Accessories

Me cha ni cal Lo ck Se riess

El ec tron ic Lo ck Se ries

        

Wel co me to us e Adv an ced  Lo ck prod uc ts. In order  to protect  yo ur righ ts an d inter ests,  read  thi s User  Man ua l caref ul ly be fore  us e. Please  

co ntact  the de al er or the man ufact urer  in case  of qu ery .

No delay function

Lock 
Signal

With Ball 
Plunger

Indicator 
Lamp

NO

Yes

Qty

Remark (s)

Remark (s)

Precautions:

 1. Installation shall be conducted as per the User Manual and the installation drawing. Cut off the power during installation and 

                           wiring. Do not carry out wiring with power connected. 
                       2. Select qualified power source and wires to avoid out of service of the lock due to abnormal power supply. It is recommended 
                           to connect the lock to the power source. 
                       3. Make sure the installation position is proper and firm. Otherwise, the bolt will lock improperly and the lock will produce heat, 
                           leading to shortening of lock service life. 
                       4. If the lock fails to work after the power is connected, check whether the permanent magnet is aligned to the magnetic 
                           induction area  and check connection correctness of the electric circuit & power source. If the multimeter is used to 
                           measure the load, make sure that voltage at lock power input end shall not be less than 12VDC. 

Access control 
power source

Access 
controller

Access control 
power source

Access 
controller

650

250

Unlock by 

disconneting power

(2000)量认(国)字(H0992)号

太平洋承保

Содержание AL-100

Страница 1: ...eration o Door Opening 90 and available for load of 250kg Electrical Property Users can select appropriate products with different models and functions based on the following table Customization is available according to users requirements 12V 15 Model Voltage DC Current mA AL 130NO AL 130NC 240 120 Mechanical Lock 3 3 5mm 1mm AL 130 Series Electric Strike Installation Drawing Electric strikes Ele...

Страница 2: ... Opening 90 and available for load of 400kg Electrical Property Users can select appropri ate products with different models and functions based on the following table Customization is available acco rding to users requirements 12V 15 Model Voltage DC Current mA Unlock Method AL 131NO 240 3 3 5mm 1mm Door Frame Electric strikes Electric strikes 150 135 100 32 48 5 28 3 44 5 AL 131NO AL 131NC NC GN...

Страница 3: ...kg Electrical Property Users can select appropri ate products with different models and functions based on the following table Customization is available acco rding to users requirements Wiring 1 One diode is an accessory provided in the accessory bag The diode is used to prevent bounce back current and voltage produced during locking or unlocking from affecting the access control mainframe Users ...

Страница 4: ...r with anode mechanical lock or ball lock in office buildings wooden doors stainless steel doors fire doors and entrance gate of residence community Product Advantage Recessed type installation pleasant looking appearance wide lock mouth and more extensive application The electromagnetic part adopts high quality magnetic materials and special processi ng workm anship to ensure normal use and no re...

Страница 5: ...blue wire refer to COM common wire NC normal close and NO normal open respectively The purple wire and orange wire output NC normal close lock signals Limited current of lock status signal is 300mA when the input voltage is 12VDC Overload is forbidden Locking and unlocking status can be monitored after it is connected to the central control room Remark can be customized Se e Diagram 1 AL 100 Door ...

Страница 6: ... Fix the lock and the decoration plate on the doorframe based on the holes Step 5 Decide the center line according to the door electric bolt lock and the bolt Then stick the perforated paper to the door Step 6 Use special drilling tool to drill holes on relevant type of magnetic buckling plate according to corresponding electric bolt lock Step 7 Fix the magnetic buckling plate on the door with scr...

Страница 7: ...6X25X48 380 760 500 250 1000 500 500 250 700 350 1000 500 253X28X55 506X28X55 280X38 5X70 AL 350 LED AL 350D LED AL 500 LED 24V 10 AL 180M 198X21X35 380 12V 10 Model Dimensions mm Voltage DC Curr ent mA Indicator Lamp Signal Output NC NO AL 350 LED 10 During installation of this product offset toward right left upside and downside of center position of both the adsorption plate and the lock shall ...

Страница 8: ... A1 166 253 253 280 D Sucking Disk H L Sucking Disk T sucking Disk Series Model Dimension Identification Electric Strike Series Magnetic Lock Series Elect ric Bolt Lock ser ies Brackets and Accessories Mechanical Lock Seriess Electronic Lock Series Electric Strike Series Magnetic Lock Series Elect ric Bolt Lock ser ies Brackets and Accessories Mechanical Lock Seriess Electronic Lock Series Push in...

Страница 9: ... rotate direction Diagram Diagram Diagram Outside Inside The sign refer to rotate direction Outside Inside Outside Inside Inside Outside Door Z bracket L bracket Outside Inside Door frame L bracket Lock body Armature plate rubber ring Z bracket Diagram of Magnetic Lock Auxiliary Bracket Installation Procedures Inward opening Door AL 180PL AL 280PL AL 350PL AL 500PL AL 500DPL AL 180PZ AL 280PZ AL 3...

Страница 10: ...ame Install the tamper screw Door frame Door frame Glass door Glass door Glass door Small metal plate for height adjustment Screw Outside Inside Step 7 Use screws to fix the sub plate and the U bracket Their positions shall be consistent Make sure the rubber ring is installed during installation AL 180PU Step 8 Installation effect Electric Strike Series Magnetic Lock Series Elect ric Bolt Lock ser...

Страница 11: ...wn in Fig 6 Glass door The U bracket clamps upwards the glass frame according to thickness use spacer of the glass door After correction of the position fix it on the glass frame Note In case both the upside and downside parts are frameless glass the distance between glass door and doorframe shall not be less than 7mm In case only one part is frameless glass the distance between glass door and doo...

Отзывы: