4
1.5 Connecting Terminal
1. Power Interface:
Used for connecting the power adapter. The voltage of series products is 24V AC and the current is
not lower than 2A. Other power is not allowed, in order to avoid damage of the cameras.
2. Network Interface:
10/100M self-adapting Ethernet interface is used to connect the camera with various network
equipments, such as, switch, router and hub. When it is connected to 10M network, the orange lamp is also on. When
it is connected to 100M network, the green lamp is always on.
3. Reset Button:
When the camera fails to function during incorrect operation or accidental failure (e.g. forget IP
address or password), or it is used in different scenes, press down the button for above 5s after a delay of 30s from
powering on to restore the camera to its factory default. The default user’s name is "
admin
", the default password is
"
admin
" and the default IP address is "
192.168.1.88
".
4. Alarm Interface:
Connect to alarm input and alarm output. When the camera receives an alarm from alarm output or
Web motion detection, this interface can send a signal to alarm output to realize real-time monitoring and overall
protection while triggering a remote alarm. The specific interfaces are presented in the following figure.
(1)
The schematic diagram of alarm input connection is as follows:
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
IN
1
2
3
4
5
NC
COM
NO
GND
Alarm input
Alarm output