8.4 Access Combination
Access Combination is when you combine different users’ verifi cation in order to gain
access. The system offers 10 different Access Combos and each combination applies to
3 Group Time Zones:
ACCESS COMBO
GROUP TIME ZONE
1
1
TP1: 0900 – 13:00
2
TP2: 1000 – 1500
3
TP3: 1300 - 1400
To use the Access Combo, users from all the three time zones must be present for veri-
fi cation and the time period of the three groups must be valid in order to gain access.
As shown in these time zones, 13:00 is the overlapping time where all of them can gain
access.
To confi gure Access Combo:
• Press Menu > Options > Access Options > Access Comb > Select the combination
you want for example Comb1 > OK > input the number, in this case 123 to represent
GRP TP1, GRP TP2, GRP TP3> OK
8.5 Lock
The opening period of the electromagnetic lock or door bolt can be controlled accord-
ing to your requirement or preference. The default value is 150 which translates to 3 sec.
50 is equivalent to 1 second.
• Press Menu > Options > Access Options > Lock > Determine the value of lock delay.
8.6 Door Sensor Delay
Door sensor delay can be confi gured to alert users if a door is not closing well after a
time period. A door sensor must be installed prior to activation of this option. The default
period is 10seconds and the maximum period is 999seconds.
• Press Menu > Options > Access Options >Dsen Delay > Determine the value of lock
delay.
8.7 Door Sensor Mode
Door sensor mode is to confi gure the time to alert an internal buzzer if the door is not
closing properly. The standard of door locking system includes:
• Normally Closed (NC): An electrical contact that regularly allows electricity to fl ow
until it is signaled to open
• Normally Open (NO).: An electrical contact that rarely allows electricity to fl ow. To
use door sensor, select NC. Press Menu > Options > Access Options > Dsen Mode >
Determine the type correctly > OK
8.8 Door Sensor Alarm
Door Sensor Alarm can be confi gured to alert users by using the alarm system if a door
is not closing well after a time period. An alarm system must be installed fi rst to use this
operation.
• Press Menu > Options > Access Options > Dsen Alarm > Determine the period > OK
Summary
* Use combo sets for
added security (2 or more
users need to verify before
access)
* Internal alarm when door
is closing properly
* Set alarm for when door is
closing within time frame
* Ensure to set maglock
time settings
* Install door sensor prior to
activating this option
17