Measuring system XS22-E2010
6 Parametrization
15
XS22_E2010
O2: 20.64 Vol%
SETTINGS
O2: 20.64 Vol%
CALIB.ZERO POINT
O2: 20.64 Vol%
CALIB. SPAN GAS
6.3 Adjustable parameters
The following parameters are adjustable in the menu SETTINGS.
OUTPUT VALUE
Valid for display
and
analog output!
Vol % O2
V
ol ppm O2, mbar O2, atm O2, Vz [mV]
OUTPUT VALUE
log[10]
linear (for Vz linear only)
OUTPUT 4 - 20 mA
Current output
ZERO: 400 ppm
Zero point 400 ppm corresponds to 4 mA
OUTPUT 4 – 20 mA
SPAN: 206400 ppm
Terminal value 206400 ppm corresponds to
20 mA
RETURN ?
NO YES
SAVE VALUES ?
NO YES