MAINTENANCE
ZIPPER MASCHINEN GmbH www.Zipper-Maschinen.at
18
ZI-BAT50 / ZI-BAT60
15.2.3
Empty the water tank
Switch off the machine.
Open the water tank door (4).
Remove the water tank and
empty the water tank
Re-insert the water tank!
Close the water tank door.
If Water tank full (19) and error
code are further displayed, remove
the water tank again and re-insert it
properly.
15.2.4
Continuous operation
In the case of a high humidity of air it is recommended to operate the dehumidifier in continuous
mode. In continuous mode it is not needed to empty the water tank.
Remove the water tank from the machine
Put the drain hose through the water outlet (14)
Re-insert the water tank
Close the water tank door
N O T I C E
Make sure that the water can flow out unhindered.
The drain hose can be extend by using a garden hose
16
MAINTENANCE
W A R N I N G
Danger due to electrical voltage! Handling on the machine can lead to serious
injuries or death. Always disconnect the machine from the power supply and secure it
against unintentional reconnection before carrying out maintenance or repair work!
The machine does not require extensive maintenance. If malfunctions and defects occur, let it be
serviced by trained persons only.
N O T I C E
Clean your machine regularly after every usage – it prolongs the machines lifespan
and is a pre-requisite for a safe working environment
Check regularly the condition of the security stickers. Replace them if required.
Check regularly the condition of the machine.
16.1
Maintenance plan
Air filter
Clean the filter in regular intervals:
Remove the air filter from Air inlet barrier (3)
Use a vacuum cleaner or slightly knock off or wash it out with water and
a mild detergent the air filter according to the contamination.
Re-insert the air filter (in dry condition!).