Section 5 Commissioning
• Shield the HydroTap G5 from direct sunlight.
• In normal operating mode. Turn the power off.
• Pull both tap levers to the forward position.
• Turn the power on.
• The safety sensor will calibrate.
• Return the levers to the neutral position.
Light intensity varies from site to site, therefore it is recommended that a re-calibration be performed at the
time of the installation. All direct sunlight must be shaded from the HydroTap G5, during the calibration.
This can be achieved by closing any nearby curtains, blinds, etc.
Pull both levers
forward
Safety
sensor
5.9 Safety sensor calibration
(Classic boiling models only)
Optional, in cases where light recalibration is required.
• Select [YES] to enable the booster.
• Before connecting the power to the booster, water must be
run through for a min. of 30 seconds to purge.
• Run the boiling tap for 30 seconds and the allow the tank to
refill.
• Connect the power supply.
• Dispense boiling water for 30 seconds and check the
booster outlet hose is warm when the boiling water tank is
replenishing.
5.7 To enable a booster
(when installed)
+
-
• Use a 6mm Allen key or a large flat-blade screwdriver to adjust the valve.
• Rotate the adjustment screw anti-clockwise to increase, and clockwise to decrease the flow.
• To measure the set flow rate, use a measuring jug or cup
and run the sparkling water for 15 seconds.
• The HydroTap has a default 15 second dispense time,
which will help in your flow rate setup.
• Multiply the amount of water dispensed in 15 seconds by 4
to determine the flow rate in litres per minute.
• The optimum flow rate is 1.6 litres per minute (400ml per
15 seconds).
• If the flow rate is adjusted too high, the carbonation tank will be emptied of water, leaving only CO2 to be
dispensed from the tap. This will result in inconsistent flow (spluttering).
5.8 Carbonation valve adjustment
(Sparkling models only)