806834 v1.02 07.21 G5 Online install instructions and user guide
4
IMPORTANT SAFETY INSTRUCTIONS
CO
2
• Keep out of reach of children.
• Use according to MSDS (material safety data sheet).
• Pressurised container. Contains gas under pressure, may explode if heated.
• Protect from sunlight.
• Do not expose to temperatures exceeding 50˚C.
• Do not expose to naked flame or any incandescent material.
• Do not pierce or burn, even after use. Avoid shock.
• High concentration of gas may cause asphyxiation.
• Use only in an upright position.
• The cylinder must be used with the supplied pressure regulator.
• The gas cylinder must be installed in an open plan area, or in an enclosed room with a volume no less
than 22m³ per 1200g cylinder, or 50m³ per 2640g cylinder.
• If more than 1 gas cylinder containing CO2 is present within the same location, the recommended
ventilated area should be in proportion to the number of gas cylinders stored in that location. A
ventilated area is a non-enclosed area which could include the kitchen, living room etc.
• Refer to the gas cylinder and MSDS for a complete list of warnings (www.zipwater.com,
www.zipwater.co.uk).
Qualifications
To avoid hazards, all installation procedures must be carried out by a suitably qualified tradesperson. The
power cable and power outlet must be in a safe visible position for connection.
Venting
Sometimes steam and / or boiling water droplets may discharge through a vent outlet on the tap. If not
using the font, ensure the tap body is located so the tap outlet safely dispenses into the sink bowl.
Lifting
Take care when lifting. The Command Centre may exceed safe lifting
limits. If you feel this is beyond your personal capabilities, please seek assistance with the lift. The weight
of the Command Centre is marked on the packaging. Do not lift the Command Centre by the front cover
or any of its connections.
Airflow
The Zip HydroTap operates within the ambient temperature range 5ºC - 35ºC. Proper air circulation must
be provided. The system will operate satisfactorily only if the recommended air gaps are provided. The
vent kit supplied must be fitted.
Altitude
Water boils at varying temperatures at different altitudes. The HydroTap adjusts for this during startup
calibration and will recalibrate itself on a regular basis.
Frost protection
If the HydroTap is located where the ambient air temperature could fall below 5ºC when the system
is not in use, do not turn off the Command Centre electrically. This safeguard does not offer the same
protection to the connecting pipework and fittings.