WARNINGS AND REGULATORY INFORMATION
• For continued safety of this appliance it must be installed, operated and maintained in
accordance with the manufacturer’s instructions.
• This appliance may deliver water at high temperature. Refer to the Plumbing Code
of Australia (PCA), local requirements and installation instructions to determine if
additional delivery temperature control is required.
• The Zip HydroTap must be earthed, earthing is provided via the supplied power cord.
The resistance of the earth connection to each exposed metal part must be less than 1Ω.
Use the power cable supplied. It is the responsibility of the installer to ensure the power
point is earthed.
• All installation and service work must be completed by trained and suitably qualified
tradespeople. Faulty operation due to unqualified persons working on this product,
may void warranty coverage.
• As the installer, it is your responsibility to supply and install all valves as required by
local regulations and relevant standards.
• The HydroTap is rated for 220-240V 50Hz AC operation.
• Do not remove the cover of the appliance under any circumstances without first
isolating the appliance from the power supply.
• Connect only to a potable (wholesome, cat1) mains water supply.
• Never locate the system near, or clean with water jets.
• Do not expose the Zip HydroTap to the elements of nature.
• The booster complies with protection class IP 20.
• For UK, a pressure limiting valve must be fitted for mains water pressures above the
max. limits stated.
• Use of tools can be hazardous, assess the risks before you start.
• A clearance envelope around all Command Centres must be provided to allow adequate
ventilation for the safe and effective use of the HydroTap system.
• The vent tray, if provided, must be fitted. It provides a safe exhaust for refrigerant gas in
the unlikely event of a leak.
• Valve and fitting threads must be sealed appropriately with PTFE tape where
compression seals are not provided.
• Always flush new filter before use.
• Do not connect booster to electrical supply until commissioning.
• Do not over tighten plumbing and hose connections.
• Braided hoses supplied cannot be lengthened.
• Be aware of the risks of hazards which could cause harm when handling compressed
CO2. Assess the risks before starting the installation.
• Do not proceed with a CO2 cylinder change if the seals are damaged. Take care not to
cross thread the regulator, a cross threaded regulator poses a potential hazard.
• Care must be taken when working with high pressure carbon dioxide, and in no case
should the normal operating pressure of 3.0 bar be exceeded.
• The power cord and general power outlet must be in a safe and accessible position
after installation. When positioning the appliance, ensure the power supply cord is not
trapped or damaged. If the power supply cord is damaged it must be replaced by a Zip
service provider or a qualified electrician.
• Do not locate multiple portable socket-outlets or portable power supplies at the rear of
the appliance.
!