   802253UK - Boiling chilled residential installation instructions - Aug 2015 -  V2.02

Major components and accessories

Accessories

Description

Booster 

(inc. connection 

hoses) 

ZT011

Scale filter

installation kit 

*ZT200G4 

Filter not included.

Font Arc / Cube, AiO

93441UK***

Font Classic / Elite 

90915UK***

Replacement  

internal 0.2 micron 

filter 

ZT402

Disabled lever kit 

SP91560

(Classic HydroTap

®

)

Mixer upgrade ***

SP91546 Classic 

SP93413 Arc

SP93414 Cube

All-in-One 

upgrade***

SP93332 (vented)

SP93331 (mains)

Recommended  

water block      

HE45004

Parts supplied

Description

Tap options

1 x

 HydroTap

®

G4 

Classic

Elite or Arc / Cube

1 x All-in-One 

 HydroTap

®

G4 

Mains or Vented

1 x Mixer tap

Classic, Arc or Cube

Command-Centre

TM

 and components

1 x Outlet vent

1 x Inlet vent

1 x

Command-Centre

TM

 

with air and water 

filters

1  x  Mains  water            

connection hose

1 x Booster inc. 

connection hoses 

(supplied with 

vented All-in-One 

and mixer tap 

models)

1 x Restrictaflow 

valve and T-piece 

(supplied with 

vented mixer taps)

1 x User guide and 

1 x Quick start 

guide

1 x Installation 

instruction

801599 - HydroTap User Guide - Nov 2013 UK - V1.05

Page 1 of 20

ZIP HydroTap

User Guide

®

Tap Operation...................(Pages 2-5)

LCD Screen & Menu .......(Pages 6-18)

Maintenance.................... (Pages 18-20)

Date of Installation.........

Affix Model Number Label 

Here

 801599

BC160/125G4

BC240/175G4

BCH160/125G4

BCH240/175G4

AV160/125G4

AN160/125G4

AV240/175G4

AN240/175G4

801600 - Zip Quick Start Guide - October 2013 - V1.06

Parts Supplied

Description

Parts Supplied

Description

1 off

Hydrotap Tap

and hoses

Duct kit

1x Air Duct

1 x Mounting 

plate

1 off

Undersink Unit 

with air and water-

filter

Vent kit

1 x Kickboard 

louvre

1 x Door vent 

louvre

1 x front vent grill

1 x Restrictaflow 

valve and Tee 

piece for Mixer 

Taps

1 off

HydroTap 

Booster heater 

and hoses

(Supplied with 

240/175 models)

1 off Mains water 

connection hose

QUICK START GUIDE

Note: This quick start guide must be read in conjunction with 

the main installation and user instructions 

• 

Before proceeding, read the installation and user instructions

• 

Check all the components are present and correct.

• 

Check that you have all the necessary tools

• 

Ensure the underbench can support the product weight when full of water,                                   

(Check the specifications in the main book and allow an extra 5-8kg when full. )

Before installing ensure the following have been provided at 

the installation site:

• 

Sufficient space in the cupboard to install all of the undersink units in accordance 

with these Installation Instructions. Refer to technical specification for dimensions. If 

required, make allowance for a booster heater. (Refer to the main book, for detailed 

installation instructions). 

• 

A potable water supply connection with isolating valve inside the cupboard within 

reach of the flexible braided hose and positioned so that the connection point and the 

stop cock will not be obstructed when all the undersink units are installed. 

• 

For Zip HydroTap 160/125 &160/175 models, a 220-240Vac, 10A GPO will be 

required. For Zip HydroTap 240/175 models, two 220-240Vac, 10A GPOs will be 

required. (One GPO is for the Zip HydroTap and the other for the Booster heater).                                                                                                                         

NOTE: Check the cable lengths and outlet positions before proceeding. 

• 

A potable cold water supply with a minimum working pressure of 172kPa and a 

maximum working pressure of 700kPa connected via an isolation valve. 

• 

For the mains pressure All-IN-ONE, both a hot and cold water supply will be required.

• 

The undersink appliances must be mounted in upright positions as shown in the 

diagrams. 

IMPORTANT!

  Do not proceed with the installation if these 

requirements are not met.

STEP 1- 

Prepare and fit the Taps

Hole positioning: 

Position the tap such that it dispenses into 

the sink bowl with ample clearance for a cup or tea pot. Alternatively, 

the tap could be mounted away from the sink using a Zip Font, avail-

able as an accessory.

Apply a light smearing of silicon sealant 

on the underside of the upper spacer to 

ensure a watertight fi t.

For HydroTap and Mixer taps 

cut a 35mm hole in the bench / sink top.

BENCH TOP

Ø35mm

HydroTap Tap

Mixer Tap 

4-in-1

 

(If required)

NUT

LOWER RUBBER 

WASHER

UPPER 

RUBBER 

WASHER

WASHER

BRAIDED 

HOSE x 3

UPPER RUB-

BER WASHER

LOWER RUB-

BER WASHER

WASHER

NUT

White Hose

Ext. Mains

Blue band

Mixer  IN

Red band

Mixer Out 

O-RING

BASE 

BLOCK  

SPIDER

BASE 

BLOCK 

NUT

USB 

CABLE

ALL 

THREAD 

ROD

NOTE: feed each of 

the tubes and elec-

trical cable evenly in 

between the legs of 

the BASE BLOCK 

SPIDER.

All-In-One Tap 

(If required)

For AIO mains and vented Taps

Cut a 50mm hole in the bench / sink top.

NOTE: make sure the tap location will allow the nozzle to drain into the sink. 

SINK TOP

50mm

ALL THREAD 

ROD

STAINLESS 

STEEL  

WASHER

SPIDER 

CLAMP

NUT

BLACK 

PLASTIC 

SPACER

NOTE: feed each of the three tubes and 

electrical cable evenly in between the legs of 

the SPIDER CLAMP when installing. 

Fit the 

STAINLESS STEEL           

WASHER, 

SPIDER CLAMP, 

AND 6mm NUT.  

6mm 

NUT

SPIDER 

CLAMP

Stainless 

washer

Black plastic 

spacer

35mm dia hole

Sink

O-RING

SINK TOP

Fit the O-ring to the underside of the AIO tap 

then pass all hoses through the 50mm hole. 

Chiller 

connection 

BLUE

From 

Mixer OUT

 to Tap - Vented version only

Boiler 

connection 

RED

Blue ring on 

RHS mains IN to

       

Mixer IN

White ring

on LHS to 

Mains in

Tap

O ring Base

Clear tube to Vent

*ZT200G4 kit to fit filters 

 *** Chrome finish part numbers are shown, 

alternative finishes are available.

Содержание HydroTap G4

Страница 1: ...ng chilled residential installation instructions Aug 2015 V2 02 Page 1 of 36 Zip HydroTap G4 Installation instructions Affix model number label here 802253UK Filtered boiling and chilled drinking wate...

Страница 2: ...omer s needs Classic HydroTap G4 range Arc Cube range Elite range All in One range Mixer range These standalone taps are directly compatible with the G4 Command CentreTM The All in One tap may be used...

Страница 3: ...Section 2 Ventilation 2 1 Ventilation for all models 21 Step 3 Install the booster and or filter softener if required Section 3 Booster installation 3 1 Booster specifications and descriptions 22 3 2...

Страница 4: ...supporting the Command CentreTM is adequate for its total weight when full of water Before commissioning Check the system has been installed correctly Check all plumbing fittings have been tightened E...

Страница 5: ...boiling and chilled models will dispense boiling water factory set to 98 C chilled water factory set to 6 10 C These units are NOT designed to be used as sanitary fixtures The Zip HydroTap G4 models...

Страница 6: ...discharge through a vent outlet on the tap If the tap is not installed using the font pedestal ensure the tap body is located so the tap outlet safely dispenses into the sink bowl area Lifting Take ca...

Страница 7: ...coverage As the installer it is your responsibility to supply if necessary and install all valves as required by local regulations and relevant standards The HydroTap G4 is rated for 230V 50Hz AC ope...

Страница 8: ...r Refer to the main book for detailed installation instructions A potable water supply connection with isolating valve inside the cupboard within reach of the flexible braided hose and positioned so t...

Страница 9: ...20 280 x 470 x 335 21 Min Max water supply pressure HydroTaps and Mains All in One taps 0 17 MPa 1 7 bar 0 7 MPa 7 bar Mixer taps and Vented All in One taps 0 2 MPa 2 bar 0 7 MPa 7 bar Booster and sc...

Страница 10: ...and CentreTM and the other for the booster The Command CentreTM must installed in accordance with IEE regulations Note Check all cable and hose lengths against inlet outlet positions before proceeding...

Страница 11: ...to suit surface being cut Hole positioning Position the tap such that it dispenses into the sink bowl with ample clearance for a cup or tea pot Alternatively the tap could be mounted away from the sin...

Страница 12: ...icon sealant on the underside of the spacer to ensure a watertight fit 1 2 All thread rod Stainless steel spacer Spider clamp Nut Black plastic spacer Cut a 35mm hole in the work sink top Note Make su...

Страница 13: ...le evenly in between the legs of the spider clamp during installation Fit the stainless steel washer spider clamp and nut Nut Spider clamp Stainless steel washer Incoming water Blue hose to chilled wa...

Страница 14: ...holes are required for the new spout height and orientation check the new plastic clip position will clear the undercut and that the USB lead will not be pinched when assembled Slide the plastic clip...

Страница 15: ...stment fixed position options Cut a 35mm hole in the work sink top Note Make sure the tap location will allow the tap spout to drain into the sink 35mm Upper o ring Base Ring Lower o ring above work s...

Страница 16: ...o the sink Note The mixer tap requires a Restrictaflow valve supplied to be fitted in the cold water supply line from the isolation valve T piece to the mixer tap see page 28 Slide upper rubber washer...

Страница 17: ...k top 50mm Fit the o ring to the underside of the AIO tap then pass tubes hoses and cable through the 50mm hole Feed each of the tubes and USB cable evenly in between the legs of the base block spider...

Страница 18: ...e red markings must be connected to the hot mains supply Do not over tighten the braided hoses Ensure that all tubes and hoses are firmly secured Blue silicone tube CHILLED OUT on Command CentreTM Cle...

Страница 19: ...op 50mm Fit the o ring to the underside of the AIO tap then pass tubes hoses and cable through the 50mm hole Feed each of the tubes and electrical cable evenly in between the legs of the base block sp...

Страница 20: ...Restrictaflow Connect the braided hose with the red marking to the metal tube with red marking then to the MIXER OUT on the Command CentreTM Ensure that all tubes and hoses are firmly secured Braided...

Страница 21: ...r side of the cupboard position A2 Where possible air inlet vent and the air outlet vent should be positioned at opposite ends of the same cupboard space Section 2 Ventilation 2 1 Ventilation for all...

Страница 22: ...zontally 3 1 Product description The booster system is a compact electronically controlled auxiliary water heater It is intended to provide pre heating of water before it enters the Zip HydroTap G4 bo...

Страница 23: ...r outlet hose must be thermally insulated with the insulation provided Tilt forward Lift up Release Note Remove the wall mounting chassis from the rear of the booster for wall mounting Take care not t...

Страница 24: ...es from the BYPASS OUT fitting on the Command CentreTM to the water inlet of the booster blue cap and from the outlet of the booster red cap to the BYPASS IN fitting on the Command CentreTM Avoid exer...

Страница 25: ...to lubricate the o rings Install cartridge with a quarter turn anticlockwise until cartridge comes to a complete stop Cartridge installation is complete Note The following instructions to flush the fi...

Страница 26: ...in place Section 4 Command CentreTM installation If no external filter is installed select position A A Rotate 90 only 1 2 3 4 4 1 External bypass valve The diverter bypass valve allows the user to ch...

Страница 27: ...nlet CANNOT be lengthened Not required for standard BC models Note All silicon tubes plastic pipes must be cut to size They must have a constant fall back to the Command CentreTM RED CLEAR BLUE BRAIDE...

Страница 28: ...T Mixer connections BRAIDED BRAIDED BRAIDED BRAIDED COLD isolation valve not supplied Restrictaflow valve T piece supplied 280mm Male to male adaptor to T piece supplied 535mm 50mm 50mm Clearance enve...

Страница 29: ...valves not supplied Tee piece not supplied RED CLEAR BLUE BRAIDED POWER CABLE USB MAINS IN MIXER OUT MIXER IN BOILING OUT BYPASS IN VENT BYPASS OUT CHILLED OUT Clearance envelope 280mm 50mm 50mm 535m...

Страница 30: ...RED CLEAR BLUE BRAIDED POWER CABLE USB MAINS IN MIXER OUT MIXER IN BOILING OUT BYPASS IN VENT BYPASS OUT CHILLED OUT Booster HT Mixer connections BRAIDED BRAIDED BRAIDED BRAIDED 280mm 50mm 50mm 535mm...

Страница 31: ...r container not supplied Note At first commissioning the system will select the filter flush screen automatically 5 2 Filter flush Prepare filter flush as per instructions and press START Boiling Chil...

Страница 32: ...levers forward Safety sensor Press the MENU button for main menu Press the Install button Press the Boost button In the next screen select YES to enable the booster Before connecting the power to the...

Страница 33: ...ed Internal fault Check ventilation call Zip Service Condenser Sensor Open Internal fault Check ventilation call Zip service Heater Fuse Driver Fault Internal fault Call Zip Service Heater Driver Faul...

Страница 34: ...ds to be disposed of separately to any other household waste Within each of the European Union member countries provisions have been made for collection and recycling of unwanted electrical and electr...

Страница 35: ...iance the use of non authorised parts or consequential damage to any other goods furnishings or property No warranty applies to the life of any filtration cartridge installed with the appliance as car...

Страница 36: ...s Aust Pty Ltd Zip products described in this publication are manufactured under one or more of the following patents AU675601 AU637412 AU635979 GB0422305 GB2065848 US4354049 US5103859 US5099825 and S...