HydroTap Installation and Operating Instructions
Page 9 of 20
Boiling Water Lever
Chilled Water Lever
Red Light White Light
Blue Light
Boiling Filter Status Chilled
Operating the mixer tap
Rotate for hot / cold water
Lift or lower
handle for ON /
OFF water flow
calibration mode. Press adjust
<
to start calibration. The element will now
cycle ON and heat the water to 95ºC maintaining it at that temperature for a
short stabilization period.
Once stabilized, the element will cycle ON, bring the water to boiling point and
hold it there for a short period.
The unit now carries out a self calibration function to ensure correct
temperatures are maintained. During this period the Red LED on the Tap Head
assembly flashes slowly until the calibration function is complete.
Once this step is complete (approx 5 minutes) the unit will default to normal
operation.
When starting, both Boiling and Chilled cycles activate simultaneously after
calibration has taken place, the descriptions below indicate what happens
during each cycle.
Boiling
The unit is now running in normal operating mode. The Red LED will flash until
usable temperature is reached.
Before using the HydroTap wait 5 minutes after this point to allow adequate fill
time. The unit is now ready for use. Test water delivery from the tap and check
for appropriate temperatures. Use cable clips to tidy and secure wiring.
Chilled
When water and power is turned ON, the Blue LED flashes slowly on the Tap
Head assembly. The compressor activates and water begins to fill the chiller
tank at the prescribed rate. When the water is chilled to 12ºC the Blue LED on
the Tap Head assembly stops flashing and stays illuminated. The compressor
continues to chill down to 5º when it will cycle Off.
Ensure that the clock matches your local time. If not refer to page 15 . If
Energy Saver Settings are required, the instructions for installing these are
described on page 15 “Setting the Energy Saver Timer”.
The Mixer tap is operated as a conventional ‘Flick Mixer’
Lifting the handle up will decrease the flow rate and lowering the handle will
increase the flow rate. Lift the handle all the way up to turn the tap off.
When the handle is moved to the left, the temperature is decreased and when
moved to the right the temperature is increased. The final temperature will be
dependant on the temperature of the incoming cold water.
The spout may be swivelled, left or right, for convenience.