Page 2 of 20
HydroTap Installation and Operating Instructions
Contents
Read these warnings first . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Models covered by these instructions . . . . . . . . . . . . . . . . . . 4
Installation requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Special tools required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Operating the mixer Tap . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Mains version connections (diagrams) . . . . . . . . . . . . . . . . . 10
Vented version connections (diagrams) . . . . . . . . . . . . . . . . . 12
Operating the HydroTap. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Replacing the filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Setting the energy saver timer. . . . . . . . . . . . . . . . . . . . . . . . 16
Auxiliary fan attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Boiling safety isolation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Setting boiling and chilled dispensing times . . . . . . . . . . . . . 18
End of life disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Trouble shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Contact details. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Hydrotap All -In -One series are able to supply Boiling and Chilled water as well as Hot and Cold water, all from the same
tap.
The ‘A’ series have their Boiling / Chilled / Hot and Cold outlets connected to the undersink (open vented) unit.
The ‘AV’ series have their Boiling / Chilled outlets connected to the undersink (open vented) unit and their Hot and Cold
mixer outlets are connected to external (Mains) Hot water and Cold water supplies.
Product description
NOTE:
All plumbing must comply with AS3500.4.1 &
AS 3500.4.2
All electrical must comply with AS/NZS 3000
All refrigeration must comply with AS/NZS
3350.2.24
The estimated temperature ranges will be:
Boiling water:
68°C - 98°C
Mixed water:
From ambient up to 30°C above ambient
Cold water:
Ambient.
Chilled water:
5°C - 10°C