        HydroTap Installation and Operating Instructions 

These Installation Instructions cover the A and AV HydroTap range. Use the chart 
on the left to identify the model you are using:

Commercial  Models:

= Boiling / Chilled and Hot / Cold.  (Mains)

AV   = Boiling / Chilled and Hot / Cold.  (Vented)

Boiling Water Capacity:

160 = 160 cups in one hour**   240 = 240 cups in one hour** 

** Capacity will be reduced by the volume of water used when operating the mixer tap.

Chilled  Water Capacity: (BCH only)

125 = 125 glasses in one hour   175 = 175 glasses in one hour

Note: 

The 

Cup

 measurement = 167mls, the 

Glass 

measurement = 200mls.

Before installing ensure that the following have been provided at the 
installation site:

•  Sufficient space in the cupboard to install the undersink unit in accordance 

with these Installation Instructions. A table of dimensions is given above.

NOTE: Add 65mm to the Depth of the undersink unit to allow for Water 
and Electrical connections. 

•  A water supply connection with isolating valve inside the cupboard 

within reach of the 750 mm flexible connection and positioned so that 
the connection point and the stop cock will not be obstructed when the 
undersink unit is installed.

Installation requirements

AV

Model 

160

Cups of 

Boiling Water 

per Hour

125

Glasses of 

Chilled Water 

per Hour

Frost Protection

If this appliance is located where the ambient air temperature could fall below 5ºC when the heater is not in use, do not 
turn off the appliance electrically. This safeguard does not offer the same protection to the connecting pipework and 
fittings.

Altitude 

The  HydroTap is equipped with a self-calibrating program which caters for altitude adjustment.       

Installation Environment Considerations

This unit is intended for indoor use only and should never be installed outdoors or exposed to the elements of nature. 
This unit must not be positioned in an area that may be cleaned by a water jet. This unit must not be cleaned by a water 
jet.

NOTE:

HydroTaps are designed to operate within 1ºC to 2ºC of boiling point and at 5ºC to 10ºC for chilled drinking water.

Read these warnings 

continued

    Commercial models covered by these instructions

Model

Height             

mm (inch)

Depth                  

mm (inch)

Width                   

mm (inch)

Weight  empty         

kg’s  lbs

Weight  full                 

kg’s  lbs

160/125

337 (13.2)

473 (18.6)

440 (17.3)

28 (61.7)

35 (77.1)

240/175

395 (15.5)

508 (20)

500 (19.6)

29.5 (65)

38 (83.7)

Содержание HydroTap All-In-One 89650

Страница 1: ...e 1 of 20 Zip HydroTap All In One Filtered Boiling and Chilled water plus Hot and Cold water for kitchens and tea rooms Installation and Operating Instructions This Installation Instruction covers the...

Страница 2: ...t details 20 Hydrotap All In One series are able to supply Boiling and Chilled water as well as Hot and Cold water all from the same tap The A series have their Boiling Chilled Hot and Cold outlets co...

Страница 3: ...y only if the recommended air gaps are provided these are 65mm min rear clearance and 50mm side clearance An air vent is provided with each unit for high usage applications this must be installed in t...

Страница 4: ...o that the connection point and the stop cock will not be obstructed when the undersink unit is installed Installation requirements AV Model 160 Cups of Boiling Water per Hour 125 Glasses of Chilled W...

Страница 5: ...t tightly against the bench sink top NOTE 1 The tap assembly must not be positioned more than 900mm above the HydroTap unit Failure to do this may result in poor water delivery NOTE 2 Under no circums...

Страница 6: ...xcess force may damage the O rings Check these joints for leaks during initial operation Measure and trim the blue silicon tube and connect it to the chilled water outlet located on the top front righ...

Страница 7: ...ovided The following instruction is CRITICAL Adjust both cupboard door hinges and attach the supplied rubber door buffers to the doors to create a 4 mm air gap between the doors and the cupboard This...

Страница 8: ...select Exit by pressing ADJUST or to confirm selection and exit model description selection setting 4 The model selection is now complete The Start Filt Flush will be displayed To continue with the fi...

Страница 9: ...usable temperature is reached Before using the HydroTap wait 5 minutes after this point to allow adequate fill time The unit is now ready for use Test water delivery from the tap and check for appropr...

Страница 10: ...TO TAP 240V GPO NOTE IF THE FLOW RATE IS TOO FAST CUT THE RED SILICONE TUBE 75mm MINIMUM FROM THE BOTTOM OF THE BASE OF THE ALL IN ONE TAP INSERT THE TEFLON RESTRICTOR ABOUT 20mm INTO THE UPPER SEGME...

Страница 11: ...65 220 BENCHTOP CABINET DOOR 4mm BUFFER PAD TO ENSURE VENTILATION GAP BRAIDED HOSE BH1 FROM MAINS SUPPLY BRAIDED HOSE BH2 FROM DOMESTIC HOT WATER SUPPLY SILICONE HOSE FROM BOILING WATER TANK IN HYDRO...

Страница 12: ...ROM STEAM VENT IN HYDROTAP TO TAP SILICONE HOSE FROM CHILLED WATER TANK IN HYDROTAP UNIT TO TAP BH1 B H 2 B H 3 NOTE IF THE FLOW RATE IS TOO FAST CUT THE RED SILICONE TUBE 75mm MINIMUM FROM THE BOTTOM...

Страница 13: ...ALL IN ONE TAP VENTED VERSION MAINS AMBIENT WATER SUPPLY ISOLATION VALVE NOT SUPPLIED 220 65...

Страница 14: ...ing slowly The light will flash slowly when the filter is due for replacement and the LCD will show Filter Change Refer to Replacing the filter section of this document Boiling Water Lever Depressing...

Страница 15: ...e where shown on the label 7 Avoid touching the filter O rings and filter opening as this may cause bacterial contamination of the cartridge 8 Moisten the O rings with water align the front cartridge...

Страница 16: ...ed Press Adjust button to increase Filter Life or Adjust button to decrease Filter Life Filter Life increases in 1000 Ltr increments to a maximum of 10000 Ltrs Reset Litres Filtered This function is t...

Страница 17: ...uto Sleep screen Press the Adjust button or Adjust button to select Enable or Disable Only after Enable has been selected can the tap head sensor be calibrated To Calibrate the sensor pull both the HO...

Страница 18: ...settings for the maximum dispensing times is 15 secs The ability to change both the Boiling and Chilled dispensing times between 5 and 15 secs in increments of 1 sec is accessible through the Menu sc...

Страница 19: ...e Child safety lock see P10 No water flow from mixer tap Faulty non return valve Check and Replace faulty non return valves 3 11 Faulty restrictaflow valve Clean and reset restrictaflow valve item 20...

Страница 20: ...37412 AU635979 GB0422305 GB2065848 US4354049 US5103859 and US5099825 Other patents are in force and patent applications are pending As Zip policy is one of continuous product improvement changes to sp...

Отзывы: