HydroTap Installation and Operating Instructions
Page 17 of 20
Setting the Energy Saver Timer
(continued)
Note:
The Hydrotap may be
temporarily activated by
operating the HydroTap levers,
the unit will go into normal
operation and then remain in
an “ON” cycle, until the next
“OFF” cycle.
Mode
>
or Mode
>
button until “Sleep Mode” is displayed.
Press
>
Adjust once to select
Option 1:
Sleep to 64ºC after 2 hours of NO USE
Press
>
Adjust once to select
Option 2:
Auto OFF after 2 Hrs of NO USE.
When the period of inactivity passes, the display will show “Sleep Mode”.
During the “Sleep Mode” the Red LED on top of the tap lever will flash slowly.
Sleep to OFF means the Boiling and Chilled circuits will be switched OFF
To de-activate the sleep mode, momentarily operate the Hot lever and then
allow sufficient time for the water to reach the set temperature
Activating ‘Sleep-when-it’s-dark’ feature
This feature will automatically switch the unit into Sleep mode Option 1 when
the ambient light falls below a set level. For this system to operate correctly
the sensor in the tap head must be calibrated for it’s surroundings.
Activation:
This can only be achieved through the service mode.
To access the service mode
Press both the Adjust
>
and Adjust
>
buttons simultaneously and hold for
several seconds, until the screen displays the HOT and COLD temperatures.
Press the Mode
>
button once to display the Auto Sleep screen
Press the Adjust
>
button or Adjust
>
button to select Enable or Disable.
Only after Enable has been selected can the tap head sensor be calibrated.
To Calibrate the sensor,
pull both the HOT and COLD levers forward while
simultaneously pressing the safety button. All the lights will flash, hold for
approximately 1 second (3 flashes) and then release.
The sensor is now calibrated for it’s surroundings. If there is any confusion
with the surrounding light, the system will revert to Normal operation mode.
To exit from the Service mode
Press both the Adjust
>
and Adjust
>
buttons simultaneously and the screen will display Normal Operation. If the
buttons are not pressed together at the same time, the Disabled option may
be selected. It is important to watch the screen to ensure the system remains
Enabled during the exit procedure. Check for correct operation by turning off
the surrounding lights.
NOTE:
When the system has entered sleep mode, due to low light conditions,
the screen will display ‘In Sleep Mode’. Operation of the Hot lever or an
increase in the ambient light, will temporarily take the system out of sleep.
Activating 7 Day Timer On / Off Mode
Press the Mode
>
or Mode
>
button until “Monday On” is displayed. To set
the time for the unit to turn on press
>
Adjust button until required time is
reached.
To set the time for the unit to turn Off press Mode
>
button once and “Monday
Off” will be displayed. Now press
>
Adjust until required time is reached.
If each individual day is to have an “On / Off” time, these steps need to be
repeated for each day and for each On / Off time.