HydroTap Installation and Operating Instructions  

                              Page 3 of 20

 Read these warnings first

Safety

This appliance is not intended for use by persons (Including Children) with 
reduced physical, sensory or mental capabilities, or lack of experience and 
knowledge, unless they have been given supervision or instruction concerning use 
of the appliance by a person responsible for their safety.

Children should be supervised to ensure they do not play with the appliance

Refrigerant

The  HydroTap Chilling unit contains 134A refrigerant under pressure. No part of 
the unit should be exposed to a naked flame. Maintenance of the refrigeration unit 
must be carried out by an accredited service provider or qualified refrigeration 
mechanic.

Qualifications

If the power cable is damaged it must be repaired only by a qualified technician. 
To avoid hazards, all installation procedures must be carried out by a suitably 
qualified tradesperson. The power cable and power outlet must be in a safe 
visible position for connection.

Venting

Sometimes steam and / or boiling water may discharge through a vent outlet at 
the mouth of the tap. It is important to ensure the tap body is located so the tap 
outlet safely drains into the sink bowl area. (see details on P10).

NOTE:

 On startup, the controls take the system through a calibration process 

which causes the unit to over-boil for a period of 90 secs. Once this mode is 
completed the system reverts back to normal operation.

Lifting

Take care when lifting the  HydroTap undersink unit. Some units may exceed 
safe lifting limits. If you feel this is beyond your personal capabilities, please seek 
assistance with the lift. The weights of the units are marked on the packaging and 
given in the table under the heading “Installation Requirements”. Do not lift the 
unit by the doors. 

Airflow

The ambient temperatures this unit should operate within are 5ºC -  35ºC. Proper 
air circulation must be provided. The system will operate satisfactorily only if 
the recommended air gaps are provided, these are 65mm min rear clearance 
and 50mm side clearance. An air vent is provided with each unit for high usage 
applications, this must be installed in the top half of the cupboard door as a 
matter of course. An accessory exhaust fan kit is available and should be used 
to ensure adequate ventilation. Make sure that the ventilation grilles of the 
undersink unit are not obstructed. 

I

ncluded in the installation pack are adhesive 

backed silicon buffers. If air vents are not installed in the cupboards housing the 
HydroTap, the buffers must be placed on the inside edge of the cupboard door to 
create a slight gap  ensuring a minimum airflow. Failure to do this may cause the 
HydroTap to overheat and operate inefficiently.

Minimum Pressure warning:

All A and AV models require a minimum cold water supply pressure of 200 kPa 
and a maximum of 700 kPa.                                                                                

Filter Control 

The  HydroTap filter control is preset to 6000 Litres to provide trouble-free flow 
and operation in most installations. Local water quality conditions may require an 
alteration to this capacity. In areas where the water has a high concentration of 
sediment, the preset litre capacity may be shortened to avoid poor flow, taste or 
odour situations. In areas where the water quality is above average, lengthening 
the preset capacity may be desirable, but not essential. If any of these changes is 
needed, follow the instructions on page 15 /16 or contact your Service Provider.

 Hydrotap undersink assembly.

The appliance must be placed in a 

horizontal position, as shown above.

Note:

Positioning of the tap assembly 
must be within the following 
parameters:

Always ensure the tubes are 
shortened so that any excess is 
removed and their route is the 
most direct line between the tap 
assembly and the HydroTap unit.

Do not allow the tubes to sag or 
droop so water is trapped within 
the hoses. Always maintain a 
constant fall.

The height between the base of 
the Hydrotap unit and the base 
of the Tap assembly cannot be 
greater than 900mm.

The power point must be located within 
reach of its cable. The appliance must be 
positioned so that the plug is accessible.

Содержание HydroTap All-In-One 89650

Страница 1: ...e 1 of 20 Zip HydroTap All In One Filtered Boiling and Chilled water plus Hot and Cold water for kitchens and tea rooms Installation and Operating Instructions This Installation Instruction covers the...

Страница 2: ...t details 20 Hydrotap All In One series are able to supply Boiling and Chilled water as well as Hot and Cold water all from the same tap The A series have their Boiling Chilled Hot and Cold outlets co...

Страница 3: ...y only if the recommended air gaps are provided these are 65mm min rear clearance and 50mm side clearance An air vent is provided with each unit for high usage applications this must be installed in t...

Страница 4: ...o that the connection point and the stop cock will not be obstructed when the undersink unit is installed Installation requirements AV Model 160 Cups of Boiling Water per Hour 125 Glasses of Chilled W...

Страница 5: ...t tightly against the bench sink top NOTE 1 The tap assembly must not be positioned more than 900mm above the HydroTap unit Failure to do this may result in poor water delivery NOTE 2 Under no circums...

Страница 6: ...xcess force may damage the O rings Check these joints for leaks during initial operation Measure and trim the blue silicon tube and connect it to the chilled water outlet located on the top front righ...

Страница 7: ...ovided The following instruction is CRITICAL Adjust both cupboard door hinges and attach the supplied rubber door buffers to the doors to create a 4 mm air gap between the doors and the cupboard This...

Страница 8: ...select Exit by pressing ADJUST or to confirm selection and exit model description selection setting 4 The model selection is now complete The Start Filt Flush will be displayed To continue with the fi...

Страница 9: ...usable temperature is reached Before using the HydroTap wait 5 minutes after this point to allow adequate fill time The unit is now ready for use Test water delivery from the tap and check for appropr...

Страница 10: ...TO TAP 240V GPO NOTE IF THE FLOW RATE IS TOO FAST CUT THE RED SILICONE TUBE 75mm MINIMUM FROM THE BOTTOM OF THE BASE OF THE ALL IN ONE TAP INSERT THE TEFLON RESTRICTOR ABOUT 20mm INTO THE UPPER SEGME...

Страница 11: ...65 220 BENCHTOP CABINET DOOR 4mm BUFFER PAD TO ENSURE VENTILATION GAP BRAIDED HOSE BH1 FROM MAINS SUPPLY BRAIDED HOSE BH2 FROM DOMESTIC HOT WATER SUPPLY SILICONE HOSE FROM BOILING WATER TANK IN HYDRO...

Страница 12: ...ROM STEAM VENT IN HYDROTAP TO TAP SILICONE HOSE FROM CHILLED WATER TANK IN HYDROTAP UNIT TO TAP BH1 B H 2 B H 3 NOTE IF THE FLOW RATE IS TOO FAST CUT THE RED SILICONE TUBE 75mm MINIMUM FROM THE BOTTOM...

Страница 13: ...ALL IN ONE TAP VENTED VERSION MAINS AMBIENT WATER SUPPLY ISOLATION VALVE NOT SUPPLIED 220 65...

Страница 14: ...ing slowly The light will flash slowly when the filter is due for replacement and the LCD will show Filter Change Refer to Replacing the filter section of this document Boiling Water Lever Depressing...

Страница 15: ...e where shown on the label 7 Avoid touching the filter O rings and filter opening as this may cause bacterial contamination of the cartridge 8 Moisten the O rings with water align the front cartridge...

Страница 16: ...ed Press Adjust button to increase Filter Life or Adjust button to decrease Filter Life Filter Life increases in 1000 Ltr increments to a maximum of 10000 Ltrs Reset Litres Filtered This function is t...

Страница 17: ...uto Sleep screen Press the Adjust button or Adjust button to select Enable or Disable Only after Enable has been selected can the tap head sensor be calibrated To Calibrate the sensor pull both the HO...

Страница 18: ...settings for the maximum dispensing times is 15 secs The ability to change both the Boiling and Chilled dispensing times between 5 and 15 secs in increments of 1 sec is accessible through the Menu sc...

Страница 19: ...e Child safety lock see P10 No water flow from mixer tap Faulty non return valve Check and Replace faulty non return valves 3 11 Faulty restrictaflow valve Clean and reset restrictaflow valve item 20...

Страница 20: ...37412 AU635979 GB0422305 GB2065848 US4354049 US5103859 and US5099825 Other patents are in force and patent applications are pending As Zip policy is one of continuous product improvement changes to sp...

Отзывы: