CV
Designation
Range Default Description
#60
7
#121
Expon. acceleration
0 - 99
0
Speed range included (Tens digit), curve (Ones digit)
7
#122
Expon. deceleration
0 - 99
0
Speed range included (Tens digit), curve (Ones digit)
7
#123
Adapt. accel./decel.
0 - 99
0
Accel. Convergence (Tens dig.), Decel. Conv.
(Ones…)
13
#124
Shunting keys, Out-
puts instead of SUSI
Bits 0-4,
6
0
Shunting key (for half speed, accel. deactivation),
Switch between SUSI
– Logic level outputs
21
#125
#126
#127
#128
#129
#130
#131
#132
Effects F0 front
F0 rear
F1
F2
F3
F4
F5
F6
0 - 255
0
Bits 1, 0 = 00: directional (active in both directions)
= 01: only forward
= 10: only reverse
Bits 7, 6, 5, 4, 3, 2 = Effect-Code, i.e.:
Uncoupler -
00110000 = “48”
Soft-Start for function output -
00110100 = “52”
Autom. Brake light -
00111000 = „56“
and so on.
23
#133
------
10
#134
Asymm. stops (ABC)
1-
14,101,,
106
Sensitivity (Hundredth), Threshold (Tens, ones digit).
8
#135
km/h - Control
2 - 20
0
= 1
Calibration run; 5, 10, 20: Relation km/ spd.
step
8
#136
km/h - Control
or:
RailCom
Contr. value after cal-run; or correct. value for Rail-
Com
22
#137
#138
#139
Smoke generator
characteristics
0 - 255
0 - 255
0 - 255
0
0
0
Eff 72,80: CV #137: PWM of FOx at stand still
CV #138: PWM of FOx at cruising speed
CV #139: PWM of FOx during acceleration
12
#140
Distance controlled
stopping
0-3,11-
13
0
= 1: HLU or ABC = 2: manual = 3: both
12
#141
Distance controlled
stopping
0 - 255
0
“Constant distance”: Stop point = 155: 500 m
12
#142
Distance controlled
stopping
0 - 255
12
High speed correction for ABC
12
#143
Distance controlled
stopping
0 - 255
0
High speed correction for HLU
1
#144
Prog,/ Update Lock
Bits 6, 7
0
Bit 6 = 1: „Service mode“-Lock, Bit 7 = 1: Update-
Lock
15
#145
------
7
#146
Gear backlash
compen.
0 - 255
0
Hundredth’ of a second at min. speed after dir.-
change
6
147,…
Experimental-
CV‘s
0 - 255
0
Special motor regulation settings
5
#151
Motor brake
0 - 9
0
= 1 … 9: Force and speed of application
18
#152
Dim Mask 2
Bits 0 - 7
0
Individual outputs exempted from dimming per CV
#60
-
#153
Continue w/o signal
0 - 255
0
Tenth of seconds: stop after losing DCC signal
-
#154
Special OEM-Bits
CV
Designation
Range Default Description
13
#155
Half-speed key
0 - 19
0
Function key selection (instead of CV #124)
13
#156
Momentum deact.
0 - 19
0
Function key selection (instead of CV #124)
13
#157
MAN key
0 - 19
0
Function key selection
4.
#158
Several sound bits +
RailCom variants
0 - 127
0
Bit 2 = 0: RailCom speed (kph)
– feedback using ID 4
= 1: Standardized feedback method using ID 7.
21
#159
#160
Effects on F7
F8
0 - 255
0
Same as CV“s #125 – 132 but for F7 and F8
25
#161
Servo Protocol
0 - 3
0
Bit 0 = 0: positive pulses , = 1: negative pulses
Bit 1 = 0: active only w. moving, = 1: always active
25
#162
#163
#164
#165
Servo 1 left stop
Servo 1 right stop
Servo 1 center stop
Servo 1 speed
0 - 255
49
205
127
30
Defines left stop position
Defines right stop position
for 3-position control
Time in tenth of seconds between left and right stop
25
#166
#167
#168
#169
Servo 2 left stop
Servo 2 right stop
Servo 2 center stop
Servo 2 speed
0 - 255
49
205
127
30
Defines left stop position
Defines right stop position
for 3-position control
Time in tenth of seconds between left and right stop
25
#170
#171
#172
#173
Servo 3 left stop
Servo 3 right stop
Servo 3 center stop
Servo 3 speed
0 - 255
49
205
127
30
Defines left stop position
Defines right stop position
for 3-position control
Time in tenth of seconds between left and right stop
25
#174
#175
#176
#177
Servo 4 left stop
Servo 4 right stop
Servo 4 center stop
Servo 4 speed
0 - 255
49
205
127
30
Defines left stop position
Defines right stop position
for 3-position control
Time in tenth of seconds between left and right stop
25
#181
#182
#183
#184
Servo 1
Servo 2
Servo 3
Servo 4
0 - 114
0
0
0
0
Operating modes (One key, two keys …)
25
#185
Special live steam
1 - 3
0
Operating settings for live steam engines
--
#186-
189
Special pantograph
configurations
-
0
Pantograph settings for special projects
5
#190 -
191
Dimming times with ef-
fect 88
0-255
Turn-ON/OFF times for effects 88, 89 and 90
3
#250,
251,
252,
253
Decoder-ID
Read-
only
-
Decoder’s serial number
3
#260,
261,
262,
263
Lade-Code
-
-
for authorization of "coded" sound-projects
-
#264
------
4
-
#265
Select sound-
collection
1, 2, 3,
…
1
= 1, 2, … 32: Select among the stored sounds
5
-
#266
Total volume
0 - 65
(255)
65
!!: >65: Over modulated, may damage speaker
Содержание MX695
Страница 6: ...Page 6 Large scale Decoder Sound Decoder MX695 6 7 9 ...
Страница 7: ...Large scale Decoder Sound Decoder MX695 MX696 MX697 MX699 Page 7 MX697 ...
Страница 8: ...Page 8 Large scale Decoder Sound Decoder MX695 6 7 9 ...
Страница 14: ...Page 14 Large scale Decoder Sound Decoder MX695 6 7 9 ...
Страница 15: ...Large scale Decoder Sound Decoder MX695 MX696 MX697 MX699 Page 15 ...