5.3.7
Temperature monitoring
•
The temperature monitoring by the PTC thermistor or temperature sensor (PT100) must be
evaluated.
•
Only connect to the inputs suitable for the relevant monitoring type.
•
Maximum permissible test voltage for PTC thermistors: 2.5 VDC.
•
When monitoring with a temperature sensor (PT100), the monitoring unit must be set to the limit
value (
°
C) speci
fi
ed in the connection diagram.
5.3.7.1
Connection diagram with PTC thermistor (PTC)
Figure 5-3-7-1-01
(1) Shielding
(2) 1 PTC thermistor per phase
(3) Attention: Do not apply any voltage > 2.5 V!
5.3.7.2
Connection diagram with temperature sensor (PT100)
Figure 5-3-7-2-01
(1) Shielding
(2) red
(3) black
5.4
Absolute encoder
Attention!
"
"
Never touch the connection contacts on the position absolute encoder or on the cable! The electronics can be
destroyed by static electricity.
"
"
You must discharge your own body before touching. This can be done, for example, by touching a conductive,
earthed object (for example bare metal switch cabinet parts) immediately before.
"
"
Operation of the elevator machine without an absolute encoder is not permissible.
Translation of the original operating instructions
ZAtop
–
model series SM210.60B/SM210.70B
Electrical installation
A-TBA17_01-GB 2023/46 Index 008Part.-No. 01013389-GB (EU-BD 1014/1)