10
Error diagnosis
10.1
General
If the ZArec4C detects an error, the RDY output drops out at the end of travel. In case of errors which
demand switching off, the /ERR output drops out immediately.
The error that occurs is displayed with error text and error number. A LED, the error memory and the
error list are available for further error diagnosis.
10.2
Acknowledgement
To acknowledge an error, you have to switch the ZArec4C off and back on.
10.3
LED
There is a LED on the ZArec4C for diagnosis.
1
1
Position of LED ZArec4C 013
2
2
Position of LED ZArec4C 026/039
Meaning of the LED
LED colour
LED status
Meaning
green
fl
ashing
Normal operation
red
fl
ashing
Display error no. by blink code: Number of blinks = Error no. - 100
Example: 8 x red blink -> Error no. 108
then 1 x white blink as a separating character
yellow
fl
ashing
Display message no. by blink code: Number of blinks = message no.
Example: 6 x yellow blink -> Message no. 6
then 1 x white blink as a separating character
10.4
Readout the error memory
Errors are saved in
the
errorlist The error list is in the Statistics/ST_LST menu. Up to 64 error
messages can be managed. Once the number of 64 messages has been reached, the oldest entry in
each case is deleted for each new error message which arises. When the error list is opened, the last
error which occurred is displayed with the following information:
Original operating instructions
ZArec4C
Error diagnosis
R-TBA14_03-GB 1817 Index 007
Part.-No. 00163436-GB
47/64