5.3
Wiring
The ZArec4C is
fi
tted with recesses and cable breakthroughs to feed the different lines into the
ZArec4C. The table and
fi
gures below show their allocation and positions.
5.3.1
Cable breakthrough of ZArec4C 013
The cables can be fed into the ZArec4C either from the side or from underneath. The cable glands are
to be mounted as required.
Control voltage cable, DC cable, brake resistance cable,
power cable
Openings on left
X-IN-OUT cable, X-CAN cable, X-PAD cable
Recess or openings on right
5.3.1.1
Side
1
3
4
2
Cable laying left side
1
Control voltage cable
2
Brake resistor cable
3
DC cable
4
Power line
5
Cable laying right side
5
X-IN-OUT cables, X-CAN cable, X-PAD cable in any order
5.3.1.2
Underneath
1
2
3
4
Cable laying left side
1
Power line
2
Brake resistor cable
3
DC cable
4
Control voltage cable
5
6
7
Cable laying right side
5,6,7
X-IN-OUT cables, X-CAN cable, X-PAD cable in any
order
5.3.2
Cable breakthrough of ZArec4C 026/039
Power line
Opening on left
Cable digital inputs and outputs, cable temperature mon-
itor brake resistor
second opening on left
Brake resistor cable
second opening on right
DC cable
Opening on right
Original operating instructions
ZArec4C
Electrical installation
R-TBA14_03-GB 1817 Index 007
Part.-No. 00163436-GB
20/64