12 Enclosure
12.1 Technical data
The rating plate data refer to devices with a power unit (PTE..) to a maximum ambient temperature of
40
°
C.
Type
Part.-No.
Rated current
{1}
max. line fuse
{2}
Integrated semicon-
ductor or device
fuse
{3}
max. heat dis-
sipation
{1}
Weight
[A]
[A]
[W]
[kg]
CTE/AHX-L
320035
-
10
0.1 A 5x20 mm
(Part. no. 00155982)
7
1,2
PTE-6AHQX-L
303608
6
10
M 10 A 5x20 mm
(pack of 10 fuses
Part.-No.349025)
20
1.5
PTE-10AHQX-L
303609
10
16
FF20 A 6x32 mm
(pack of 10 fuses
Part.-No.349026)
40
2,5
{1} For mains voltage 230 V / 50 Hz, values for different speci
cations on request
{2} Max. supply side
line fuse
according to DIN EN 60204-1 classi
cation VDE0113 chapter 1
{3} Integrated semiconductor fuse in device (no line safety switch)
Line voltage
1 ~ 230 V (-15...+10 %), 50/60 Hz
Output voltage (PTE..)
approx. 0 - 100 % of appliedmains voltage
Min. Motorcurrent (PTE..)
approx. 0.2 A
Voltage supply e.g. for sensors
+24 V
±
20 %, I
max
50 mA
Output (0 - 10 V)
I
max
10 mA (short-circuit-proof)
Contact rating of the internal relay
max. AC 250 V 5 A
Max. permissible ambient temperature PTE..: 40
°
C (up to 55
°
C with derating)
CTE..: 55
°
C
Min. permissible ambient temperature 0
°
C (if mains voltage is not switchedoff up to -20
°
C)
Max. permissible installation height
0...4000 m amsl
above 1000 m amsl the ratedcurrent is to be reducedby 5 % / 1000 m
Permissible rel. humidity
85 % no condensation
Electromagnetic compatibility for the
standard voltage 230 / 400 V accord-
ing to DIN IEC 60038
Interference emission EN 61000-6-3 (domestic household applications)
Interference immunity EN 61000-6-2 (industrial applications)
Harmonics current according (PTE..)
In accordance with EN 61000-3-2
Up to a maximum current of 4 A, the limits are adhered to with no restrictions.
Housing protection
IP54
Operating Instructions
UNIcon / Acontrol
Enclosure
L-BAL-E051-GB 1035 Index 003
Part.-No. 00163311-GB
72/83