3. For Acknowledgement press
|
ESC
|
or
“
Alarm Off
”
for a few seconds (in versions with key no. 7). The fault
message is switchedoff by the relay
“
K1
”
.
4. As long as a malfunction exists after con
rmation =
“
Alarm pause
”
, the alarm symbol remains lit. If the error
continues (e.g. due to sensor breakage), a message reappears after the adjustable time period for an
“
Alarm
pause
” –
factory set to 60 minutes).
S:25
°
C SH:99%
5. In the menu group overview,
“
Alarm pause
”
appears alternately with the con
rmedalarm message.
Alarm
Overtemp.
6. Past fault messages can be queriedin the alarm list.
Overtemp.
Latest alarm = overtemperature
P
↓
00029:49:07
Controllers periodof operation at time of message
P
↓
ED1: - -
ED: Event data at the time of the fault message (not yet fully
occupied)
9.4.2
Example for overtemperature message in stall 3 when networking
Cot 1 MASTER
Cot 2 (Slave 1)
Cot 3 (Slave 2)
S:20
°
C KL:56%
S:22
°
C KL:42%
S:25
°
C SH:99%
Common alarm
Overtemp.
Operating Instructions
UNIcon / Acontrol
Settings for operation
L-BAL-E051-GB 1035 Index 003
Part.-No. 00163311-GB
56/83