![ZIEHL-ABEGG Fcontrol FTET4AHMQ-L Скачать руководство пользователя страница 70](http://html1.mh-extra.com/html/ziehl-abegg/fcontrol-ftet4ahmq-l/fcontrol-ftet4ahmq-l_operating-instructions-manual_3698482070.webp)
9.6
Increase program
Day of program
Day of program
The current program day and the hour are displayed here additionally for information.
↑
|
ESC
|
P
↓
9.6.1
Set the trajectory of the growth curve
Actual day
Actual day
Setting the program day Also serves to reset the program to the beginning (day =0)
Setting range: 0...360 day
Factory setting: 0 day
Curve program
Curve program
Curve program = ON Wachstumsprogramm activated.
The curve types can be activated or deactivated in the following settings:
|
Setpoint curve
|
,
|
Min. curve
|
,
|
Max. curve
|
,
|
Heating1 curve
|
,
|
Heating2 curve
|
The appropriate
“
normal settings
”
of the named functions are then superposed by the
calculated curve values (
following diagrams).
That means the curve values in
fl
uence the regulation with an active growth curve.
Knick point1
Knick point1
Setting Day for break point 1 (
following illustration)
Setting range: 1...120 day
Factory setting: 10 day
Knick point2
Knick point2
Setting Day for break point 2 (
following illustration)
Setting range: 1...120 day
Factory setting: 60 day
Final day
Final day
Setting Day for Final day (
following illustration )
Setting range: 1...360 Day (depending on break points)
Factory setting: 120 day
Information
The kinks and the end point act commonly on all curves: Setpoint, Minimum ventilation, Maximum
ventilation, Heating 1, Heating 2
Operating Instructions
Fcontrol
–
model series FTET4/6/10AHMQ-L
Settings for operation
L-BAL-E139-GB 2022/03 Index 006
Part.-No.